Stripping Voltammetry of Mercury(II) and Lead(II) Ions at Liquid/Liquid Interface.
نویسندگان
چکیده
منابع مشابه
Aptasensors Based on Stripping Voltammetry
Aptasensors based on stripping voltammetry exhibit several advantages, such as high sensitivity and multi-target detection from stripping voltammetric technology, and high selectivity from the specific binding of apamers with targets. This review comprehensively discusses the recent accomplishments in signal amplification strategies based on nanomaterials, such as metal nanoparticles, semicondu...
متن کاملDetermination of Tl(I) Ions in Homeopathic Drugs by Differential Pulse Anodic Stripping Voltammetry
Objectives: The present study is focused on the determination of thallium (I) ions in homeopathic drugs. Methods: The determination was carried out using the Differential Pulse Anodic Stripping Voltammetry (DPASV) technique coupled with the flow-injection measuring system (FIA-DPASV). Results: The thallium content was analyzed in two commercial homeopathic preparations (Thallium aceticum 5CH an...
متن کاملDetermination of trace metal ions in common salt by stripping voltammetry.
Sensitive voltammetric methods using cathodic and anodic differential pulse stripping techniques were applied for determination of trace ions cadmium(II), cobalt(II), copper(II), lead(II), manganese(II), nickel(II), and zinc(II), which are usually found in different grades of common salt as contaminants. The optimal conditions, i.e., deposition time, preconcentration potential, supporting elect...
متن کاملDetermination of Aminophylline by Cathodic Stripping Voltammetry
Aminophylline is determined by cathodic stripping voltammetry (CSV) in BR buffer, pH 7.5 at a hanging mercury drop electrode. The detection limit was 3x10 M after 60 s accumulation at -0.60 V versus Ag/AgCl reference electrode. The linear range demonstrated up to 5x10 M using CSV. The interference caused by some purine derivatives, anions and some metal cations on the peak current was studied. ...
متن کاملDetermination of chitosan by cathodic stripping voltammetry.
A sensitive method for the determination of chitosan (CTS) by cathodic stripping voltammetry is presented. The method exploits a pair of oxidation-reduction peaks of CTS at -0.62 V (vs. SCE) and -0.54 V (vs. SCE), and an enhancement of the peak current of CTS observed in a 0.05 mol l(-1) potassium hydrogenphthalate buffer solution (pH 2.5). The peak current is linear with the concentration of C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1998
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.14.63