Structural Dynamic Response of an Unreinforced Masonry House using Non-Destructive Forced Vibration

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexural Tension in Unreinforced Masonry

Unreinforced masonry is that in which the tensile strength of the masonry is taken into consideration in design. Allowable out-of-plane tensile stress values are a function of the mortar type, such as Portland cement/lime mortar vs. masonry cement mortar or type M or S mortar vs. type N mortar. The allowable tensile stress is also a function of the masonry construction, such as tension parallel...

متن کامل

Effective stiffness of unreinforced brick masonry walls

Code design of Unreinforced Masonry (URM) buildings is based on elastic analysis, which requires as input parameter the effective stiffness of URM walls. Current approaches estimate the effective stiffness as fixed ratio of the gross sectional stiffness but comparisons with experimental results have shown that this does not yield satisfactory predictions. In this paper, a recently developed ana...

متن کامل

Testing unreinforced masonry structures at reduced scale

When testing multi-story structures on a shaking table, most testing facilities require a reduced scale model. Producing scale test units at small scale is particularly challenging for unreinforced masonry structures. Previous work by other researchers showed that scaling of units and mortar joints is mandatory in order to obtain for the reduced scale masonry failure modes, which are similar to...

متن کامل

Modelling of the Cyclic Response of an Unreinforced Masonry Wall through a Force Based Beam Element

The seismic assessment of existing masonry buildings is based on the prediction of their nonlinear response under lateral loading. This requires a reliable estimation of the force and displacement demand. For this purpose, modelling strategies using structural component elements are widely applied both in research and in engineering practice, since they can provide a satisfactory description of...

متن کامل

Damage Accumulation in Unreinforced Masonry Due to Seismic Loading

Masonry has low cohesive strength and is susceptible to the brittle failure, when subjected to induced tensile stresses. It fails due to lateral tensile stresses even when masonry prisms are tested in uni-axial static compression and the stress-strain curve remains almost linear up to failure. Although masonry normally resists compressive forces, under lateral in-plane cyclic loads some parts o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Earthquake Engineering

سال: 2015

ISSN: 1363-2469,1559-808X

DOI: 10.1080/13632469.2015.1051247