Structure Vibration Analysis and Active Noise Control of Power Transformer

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of decentralized active control of power transformer noise

The active noise control of sinusoidal sound in free space has received considerable attention in the last few years. In a number of practical situations, the sound radiated in free space by extended sources needs to be globally reduced. This is the case of electrical power transformers, for example [1]. Nelson and Elliott have demonstrated that sound power attenuation can be achieved by active...

متن کامل

Piezoelectric Power Requirements for Active Vibration Control

This paper presents a method for predicting the power consumption of piezoelectric actuators utilized for active vibration control. Analytical developments and experimental tests show that the maximum power required to control a structure using surface-bonded piezoelectric actuators is independent of the dynamics between the piezoelectric actuator and the host structure. The results demonstrate...

متن کامل

Structure-vibration Analysis of a Power Transformer(154kV/60MVA/Single Phase)

The most common cause of power transformer failures is mechanical defect brought about by excessive vibration, which is formed by the combination of multiples of a frequency of 120 Hz. In this paper, the types of mechanical exciting forces applied to the power transformer were classified, and the mechanical damage mechanism of the power transformer was identified using the vibration transfer ro...

متن کامل

Flexible Power Electronic Transformer for Power Flow Control Applications

This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...

متن کامل

Analysis of Vibration Characteristics of PD Control Active Magnetic Bearing and Cracked Rotor System (RESEARCH NOTE)

Crack fault of rotor is one of the most prominent problems faced by magnetic bearing rotor system. In order to improve the safety performance of this kind of machinery, it is necessary to research the vibration characteristics of magnetic bearing cracked rotor system. In this paper, the stiffness model of the crack shaft element was established by the strain energy release rate (SERR) theory. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Transactions of The Korean Institute of Electrical Engineers

سال: 2013

ISSN: 1975-8359

DOI: 10.5370/kiee.2013.62.12.1771