Studies on a Pb2+ - selective electrode with a macrocyclic liquid membrane: Potentiometric determination of pb2+ ions

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of a New Macrocyclic -PVC Electrode to Potentiometric Studies of Fe(III) Ion

A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....

متن کامل

A highly selective fluorescent chemosensor for Pb2+.

A new fluorescent sensor based on rhodamine B for Pb2+ was synthesized. The new fluorescent sensor showed an extreme selectivity for Pb2+ over other metal ions examined in acetonitrile. Upon the addition of Pb2+, an overall emission change of 100-fold was observed, and the selectivity was calculated to be 200 times that of Zn2+. The signal transduction occurs via of reversible CHEF (chelation-e...

متن کامل

A New Liquid Membrane Electrode for Selective Determination of Caffeine

A new liquid membrane electrode for caffeine prepared from a solution of caffeine-picrylsulfonate ion-pair complex in n-octanol is developed. It exhibits Nernstian response in the range of w-·2 to 10M caffeine with a cationic slope of 59 mY/concentration decade. The electrode has a wide working pH range (5.59.5), fast response time (20 seconds1.5 minutes), stable response for at least 30 days a...

متن کامل

Kinetic potentiometric determination of creatinine in serum with a picrate ion-selective membrane electrode.

We describe a new kinetic method for potentiometric determination of creatinine in serum, based on the creatinine--picrate reaction in alkaline medium (Jaffé reaction). The reaction is monitored with a picrate-selective electrode, and the increase in electrode potential during 270 s is measured and related directly to the creatinine concentration. Small cation-exchange columns are used to separ...

متن کامل

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Serbian Chemical Society

سال: 2006

ISSN: 0352-5139,1820-7421

DOI: 10.2298/jsc0612345i