Studies on Copper-histidine Chelate. (2) : Polarographic Determination of Stability Constant

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Structure of Copper (II) -Histidine Chelate

The binding of Cu(II) by histidine in 1: 2 molar ratio has been investigated. The theoretical number of hydrogen ions displaced from each mole of bound llgand at several pH values was calculated considering all the possible interactions between Cu(II) and histidine involving (a) amino and carboxyl, (b) amino and imidazole, (c) imldazole and carboxyl, and (d) amino, imidazole, and carboxyl group...

متن کامل

Determination of Copper (II) and Palladium (II) by Polarographic Methods

Schiff base 2–Hydroxy–5–methoxy Benzaldehyde – Tris [HMBT] Ligand is a new chromogenic reagent have not been used so far for the determination of copper and palladium in trace quantities. Effect of p H on wave height for COPPER[HMBT] PALLADIUM –[HMBT] systems have been studied at p H 7-8.5 and 8.5-11.5 for Copper and Palladium respectively in 0.1 m molar NaNo3 and 0.002 % Triton –x–100 which in...

متن کامل

Determination of the Stability Constant of Vanadium (V) with Alaine

Formation equilibria of dioxy vanadium (V) complex with alanine in acidic media (pH<2.3) has been investigated potentiometrically and spectrophotometrically. In this condition the 1:1 complex has the formula VO2Y, where Y¯ represent the fully dissociated aminocarboxylate anion. The stability constant of VO2Y was determined as log KVO2Y=11.32±<e...

متن کامل

Polarographic determination of malononitrile.

A procedure is proposed for the determination of malononitrile by differential pulse polarography in methanolic 0.1M tetraethylammonium iodide/0.001M tetramethylammonium hydroxide as the supporting electrolyte. In this medium malononitrile is chemically converted into an electroactive species. With close control of timing of the steps in the procedure the error of the method is +/-1.5% in the c...

متن کامل

Determination of the stability constant of Cobalt (ІІ) – Piroxicam complex by spectrophotometery

In this work, a new spectrophotometric method for the determination of trace amount of Cobalt (ІІ) ionwas investigated and the stability constant of the related complex was evaluated 2.174 × 104. In the Cobalt(ІІ)-piroxicam complex, the maximum absorbance wavelength is 570 nm and the linearity of calibrationcurve was investigated (5-10 ppm). The relative standard deviation for seven replicate e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: YAKUGAKU ZASSHI

سال: 1967

ISSN: 0031-6903,1347-5231

DOI: 10.1248/yakushi1947.87.5_507