Studies on inlet reverse flow for open-type centrifugal impeller.
نویسندگان
چکیده
منابع مشابه
Investigation into Influence of Inlet Prewhirl on Flow Field of Diagonal Impeller with Exit Guide Volute
By means of setting inlet pre-rotator ,the inlet and exit flow field of the diagonal flow impeller with exit guide volute have been measured with 5 holes probe, in different flow conditions, and in the conditions of positive and negative pre-rotating. The expe1iment results are compared with that of without the pre-rotator.
متن کاملEffect of impeller geometry on performance characteristics of centrifugal compressor
Centrifugal Compressors play an essential role in oil, gas and petrochemical industries. Their extensive usage is due to their smooth operation and high reliability compared to other other compressor types. One of the main characteristics of these turbomachines is their performance curve, which is an important criterion for selecting the appropriate compressor for a desired working condition. I...
متن کاملCavitating Vortex Flow Generated by a Stationary Volute Casing and a Rotating Centrifugal Impeller
Three devices for treating contaminated water using a cavitating vortex have been developed and tested. The first device uses stationary twin volute casings to generate cavitating vortices. Observation of the collisions among the opposing counter-rotating vortices revealed that their end portions whirl, that the vortices never collide head-on, and that they eventually separate into several smal...
متن کاملNumerical Calculation of the Flow in a Centrifugal Pump Impeller Using Cartesian Grid
The simulation of the three-dimensional turbulent flow in turbomachines is currently based on the solution of the Reynolds Averaged Navier Stokes equations. A considerable computational effort usually goes to the mesh generation process due to the complexity of the impeller geometry. The use of Cartesian grids combined with a numerical technique for solving partially blocked cells is presented ...
متن کاملArterial-venous perfusion without anticoagulation: the impeller centrifugal pump.
A study was designed to test the effects of the absence of anticoagulation in the extracorporeal circuit. Five swine were subjected to this experiment utilizing the impeller centrifugal pump during which neither heparin nor any other anticoagulant was used. The extracorporeal circuit consisted of polyvinylchloride tubing, a Centri-Med pump and an external stainless steel heat exchanger that was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
سال: 1990
ISSN: 0387-5016,1884-8346
DOI: 10.1299/kikaib.56.3779