Study of Label-free Bi-analyte Detection Aptamer Biosensor
نویسندگان
چکیده
منابع مشابه
Label-free aptamer-based electrochemical impedance biosensor for 17β-estradiol.
A novel aptamer-based label-free electrochemical impedance spectroscopy biosensor for 17β-estradiol has been fabricated. The aptamers were firstly immobilized on the gold electrode through Au-S interaction; the aptamer probe was then bound with the addition of 17β-estradiol to form the estradiol/aptamer complex on the electrode surface. This leads to a significantly larger interfacial electron ...
متن کاملLabel-free detection of cardiac biomarker using aptamer based capacitive biosensor
An aptamer based capacitive label-free biosensor was developed for the detection of a cardiac biomarker (C-reactive protein, CRP), based on charge distribution under the applied frequency by Non-Faradaic Impedance Spectroscopy. This capacitive biosensor is based on reagentless processing and developed using gold-interdigitated (GID) capacitor arrays functionalized with synthetic RNA-aptamers. T...
متن کاملLabel-free RNA aptamer-based capacitive biosensor for the detection of C-reactive protein.
In this study, we report a novel aptamer-based capacitive label-free biosensor for monitoring transducing aptamer-protein recognition events, based on charge distribution under the applied frequency by non-Faradaic impedance spectroscopy (NFIS). This approach to capacitive biosensors is reported for the first time in this study, is reagent-less in processing and is developed using gold interdig...
متن کاملBiosensor Array for Label-Free Biomolecular Detection
Biosensors are one of the fundamental detection platforms in biotechnology. They take advantage of unique biomolecular interactions to capture and detect specific analytes on a surface. The detection versatility of biosensors has always been their key advantage and it has been demonstrated that they can detect almost any analyte such as DNA, proteins, metabolites, and even micro-organisms. Howe...
متن کاملHigh-Speed Label-Free Multi-Analyte Detection through Micro- interferometry
Interferometers can detect optical path changes down to a billionth-lambda at the half intensity point at quadrature, (defined when the signal and reference waves are out of phase by ninety degrees). We have fabricated interferometric microstructures on silicon all operating at quadrature. The ultimate capability of this approach is the fabrication of over a billion interferometric biosensors o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Chimica Sinica
سال: 2013
ISSN: 0567-7351
DOI: 10.6023/a12110911