Study of Magnetic Micro-Ellipses by Cantilever Sensor
نویسندگان
چکیده
منابع مشابه
SiGeC Cantilever Micro Cooler
The fabrication and characterization of SiGeC cantilever microcoolers are described. Silicon on insulator (SOI) was used as the substrate, and two layers of 3 μm p-SiGe0.07C0.0075 and 1.14 μm n-SiGe0.07C0.0075 lattice matched to silicon were grown using molecular beam epitaxy. The uni couple cooler was fabricated using conventional integrated circuit (IC) processing, and the cantilever structur...
متن کاملNumerical study of induction heating by micro / nano magnetic particles in hyperthermia
Hyperthermia is one of the first applications of nanotechnology in medicine by using micro/nano magnetic particles that act based on the heat of ferric oxide nanoparticles or quantum dots in an external alternating magnetic field. In this study, a two-dimensional model of body and tumor tissues embedded is considered. Initially, the temperature distribution is obtained with respect to tumor pro...
متن کاملstudy of cohesive devices in the textbook of english for the students of apsychology by rastegarpour
this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...
Influence of Shape Design of MEMS (Micro-Cantilever Based Sensor) on High-Sensitivity
In this paper, a novel analysis was carried out on the biosensor microcantilevers in order to increase the sensitivity of a microcantilever based biosensor piezoresistive. Holes were made and compared with the basic rectangular (R), triangular (T), and step(S) profile cantilever. Effect of changing the micro-cantilevers profile and its cross-section shape was investigated. A finite element ANSY...
متن کاملUnderstanding interferometry for micro-cantilever displacement detection
Interferometric displacement detection in a cantilever-based non-contact atomic force microscope (NC-AFM) operated in ultra-high vacuum is demonstrated for the Michelson and Fabry-Pérot modes of operation. Each mode is addressed by appropriately adjusting the distance between the fiber end delivering and collecting light and a highly reflective micro-cantilever, both together forming the interf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Physica Polonica A
سال: 2017
ISSN: 0587-4246,1898-794X
DOI: 10.12693/aphyspola.131.833