Study of Magnetic Micro-Ellipses by Cantilever Sensor

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SiGeC Cantilever Micro Cooler

The fabrication and characterization of SiGeC cantilever microcoolers are described. Silicon on insulator (SOI) was used as the substrate, and two layers of 3 μm p-SiGe0.07C0.0075 and 1.14 μm n-SiGe0.07C0.0075 lattice matched to silicon were grown using molecular beam epitaxy. The uni couple cooler was fabricated using conventional integrated circuit (IC) processing, and the cantilever structur...

متن کامل

Numerical study of induction heating by micro / nano magnetic particles in hyperthermia

Hyperthermia is one of the first applications of nanotechnology in medicine by using micro/nano magnetic particles that act based on the heat of ferric oxide nanoparticles or quantum dots in an external alternating magnetic field. In this study, a two-dimensional model of body and tumor tissues embedded is considered. Initially, the temperature distribution is obtained with respect to tumor pro...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

Influence of Shape Design of MEMS (Micro-Cantilever Based Sensor) on High-Sensitivity

In this paper, a novel analysis was carried out on the biosensor microcantilevers in order to increase the sensitivity of a microcantilever based biosensor piezoresistive. Holes were made and compared with the basic rectangular (R), triangular (T), and step(S) profile cantilever. Effect of changing the micro-cantilevers profile and its cross-section shape was investigated. A finite element ANSY...

متن کامل

Understanding interferometry for micro-cantilever displacement detection

Interferometric displacement detection in a cantilever-based non-contact atomic force microscope (NC-AFM) operated in ultra-high vacuum is demonstrated for the Michelson and Fabry-Pérot modes of operation. Each mode is addressed by appropriately adjusting the distance between the fiber end delivering and collecting light and a highly reflective micro-cantilever, both together forming the interf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Physica Polonica A

سال: 2017

ISSN: 0587-4246,1898-794X

DOI: 10.12693/aphyspola.131.833