Appropriate energy window width for gamma camera [Persian]

Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...

متن کامل

appropriate energy window width for gamma camera [persian]

introduction: scatter radiation is one of the major sources of error in nuclear medicine data processing. different methods of scatter correction have been introduced in order to improve the quality of data. however the best method is to avoid recording of scatter photons in acquisition. the only difference between scattered and non-scattered photons is the energy. pulse height analyzer is the ...

متن کامل

Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

متن کامل

Study of the effect of energy window width and peak shift on SPECT images to evaluate false diagnosis

Introduction: The different factors that affect the camera uniformity of Single Photon Emission Computed Tomography (SPECT) technique have been analyzed including peak shift (%) and window width of energy. The effect of peak shift and window width on SPECT image uniformity has been investigated using a point source to perform intrinsic flood images. Methods:</stro...

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...