Study on characteristics and calculation method of VSC-HVDCshort circuit current under three-phase AC short circuit

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short Circuit Calculation Methods

All electrical systems are susceptible to short circuits and the abnormal current levels they create. These currents can produce considerable thermal and mechanical stresses in electrical distribution equipment. Therefore, it's important to protect personnel and equipment by calculating short-circuit currents during system upgrade and design. Because these calculations are life-safety related, ...

متن کامل

A New Circuit for Three-phase to Three-phase Ac/ac Matrix Converters

The conventional AC/AC matrix converter uses 9 bidirectional switches. The 3×3 switches give 512 combinations of switching states, which are decreased to only 27 feasible states, if the two basic rules (preventing the short-circuit and open-circuit) to operate the converters safely are applied. The output voltage of a basic matrix converter is limited to 866 . 0 2 3 ≈ of the input voltage. In t...

متن کامل

Short Circuit and Induced Voltage Transient Study on a Planned 1000 MW HVDC-VSC Cable Link

TERNA, the Italian TSO, is planning new HVDC interconnections with neighboring countries including underground links based on VSC technology; short circuit transient studies of such links require accurate cable line modeling in a frequency range from dc to 10 kHz at least. The finite section approach was used to this purpose. Short-circuit transient simulation results evidenced significant temp...

متن کامل

An Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices

Nowadays, high-voltage circuit breakers have reached such high short-circuit capabilities that testing them under the full rated voltage is generally not possible with direct tests, and they are conducted by using the synthetic test methods. Although the phenomena associated with making tests is of particular importance especially in case of load break switches, but making tests are rather d...

متن کامل

Load Flow Calculation and Short Circuit Fault Transients in AC Electrified Railways

A load flow and short circuit fault simulation of AC electrified railway distribution systems is presented with DIgSILENT PowerFactory software. Load flow of electrified railways distribution system with concerning multi train lines and dynamic characteristics of train load is studied for different time laps. The dynamic characteristics of train load in starting and braking conditions with diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP Conference Series: Earth and Environmental Science

سال: 2020

ISSN: 1755-1315

DOI: 10.1088/1755-1315/446/4/042079