Study on seismic performance of base-isolated and base-fixed Ancient timber buildings in hanging-wall/footwall Earthquakes

نویسندگان

چکیده

This study aims to quantify effects of hanging-wall/footwall fault parameters on dynamic responses base-isolated and base-fixed ancient timber buildings. Finite element models a real building with without isolation technology are first built verified by comparison existing studies. Fitting analysis three typical models, Abrahamson-Silva-Kamai, Campbell-Bozorgnia Chiou-Youngs as well 622 recorded ground motions, is then conducted determine the optimal model generate earthquake waves. Finally, seismic performance based-isolated buildings investigated. The results show that Abrahamson-Silva-Kamai achieves best fitting lowest computational errors. Isolation can improve for different ages. effectiveness decreases increasing ages in parameters. remains unchanged dip angles footwall earthquakes, whereas it increase hanging-wall earthquakes at same site distance. structural better than earthquakes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Study of Sliding Base-Isolated Buildings with Magnetorheological Dampers in Near-Fault Earthquakes

The increase in bearing displacements of sliding isolated buildings due to near-fault earthquakes, with long-period pulse type of ground motion, is an important problem. Often, supplemental nonlinear passive dampers are incorporated into the isolation system to reduce the base displacements; however, this may increase the interstory drifts and accelerations in the superstructure. Hence, there i...

متن کامل

A Comparative Study on the Seismic Performance of Superelastic-Friction Base Isolators against Near-Field Earthquakes

This paper presents a comparative seismic performance assessment of superelastic-friction base isolator (S-FBI) systems in improving the response of bridges under near-field earthquakes. The S-FBI system consists of a steel-Teflon sliding bearing and a superelastic shape memory alloy (SMA) device. The other isolation systems considered here are lead rubber bearing (LRB), friction pendulum syste...

متن کامل

Self-Tuning Fuzzy Control for Seismic Protection of Smart Base-Isolated Buildings Subjected to Pulse-Type Near-Fault Earthquakes

Pulse-type near-fault earthquakes have obvious long-duration pulses, so they can cause large deformation in a base-isolated system in contrast to non-pulse-type near-fault and far-field earthquakes. This paper proposes a novel self-tuning fuzzy logic control strategy for seismic protection of a base-isolated system, which can operate the control force of the piezoelectric friction damper agains...

متن کامل

Diagnosis method for seismic performance of Japanese traditional timber buildings

First in this paper, the guidelines of diagnosis for the seismic performance of traditional timber buildings are introduced which are under development in a committee of the Agency for Cultural Affairs of Japan. Next, the evaluation method of seismic performance proposed in the diagnosis is summarized. Next, as calculation examples, the lateral loaddisplacement relationships of five temple buil...

متن کامل

Seismic Design of Base-Isolated Buildings in Mexico. Part 1: Guidelines of a Model Code

The updated version for the Manual of Civil Structures (MOC), a model seismic code in Mexico, was published in 2008. MOC also is incorporating guidelines for the seismic design of base-isolated structures this year 2012, being the first Mexican code to include such recommendations. This paper summarizes the most relevant aspects of these guidelines, their relations to other guidelines worldwide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Asian Architecture and Building Engineering

سال: 2022

ISSN: ['1346-7581', '1347-2852']

DOI: https://doi.org/10.1080/13467581.2022.2045999