STUDY ON SEISMIC RESPONSE REDUCTION OF SINGLE-STORY ANTI-SYMMETRIC Z-TYPE NC BRACED FRAME

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Fling-Step on Seismic Response of Steel Eccentrically Braced Frame Structures

Fling-step and forward directivity are two important characteristics of near-field earthquakes. Forward directivity occurs when the rupture propagates toward the site and arises in fault‐normal direction for strike‐slip faults. Fling-step is the consequence of permanent ground displacement imposed by near-field earthquakes and arises in strike-slip faults in the strike parallel direction. Fling...

متن کامل

Seismic Behavior of Asymmetric Two-Story X-braced Frames

Concentrically braced frames (CBFs) are one of the efficient lateral load resisting systems in high seismicity regions. One of the common problems with the use of concentrically braced frames is limitation in the architectural application and position of the openings. Two-story X braced frames have more advantages than other configurations of concentrically braced frames, since in many cases th...

متن کامل

The Effect of Frame Geometry on the Seismic Response of Self-Centering Concentrically- Braced Frames

Conventional concentrically-braced frame (CBF) systems have limited drift capacity before brace buckling and related damage leads to deterioration in strength and stiffness. Self-centering concentrically-braced frame (SC-CBF) systems have been developed to increase drift capacity prior to initiation of damage and minimize residual drift. SC-CBFs differ from conventional CBFs in that the SC-CBF ...

متن کامل

Evaluation of the Seismic Response of Single-Story RC Frames under Biaxial Earthquake Excitations

This paper summarizes the lessons learned from a full-scale test on two RC frame prototypes that have recently been tested on LNEC shaking-table using four pairs of biaxial synthetic ground motion records during 15WCEE Conference (2012). The reference structures are two single-story RC frames which are geometrically identical but with different reinforcement details. The simplified inelastic mo...

متن کامل

Effect of column-foundation connection stiffness on seismic performance of rocking steel braced frame

Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)

سال: 2014

ISSN: 1340-4202,1881-8153

DOI: 10.3130/aijs.79.1677