STUDY ON TOMOGRAPHY REPORT II : SCATTERING X-RAY

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-ray scattering tomography for biological applications.

The conventional attenuation contrast imaging does not yield satisfactory sensitivity and specificity for weakly absorbing media, such as biological soft tissues. The x-ray scattering offer an important contrast mechanism to reveal structural features and density fluctuation within an object. This scattering signal carries information at the molecular and supra-molecular level, and has a tremen...

متن کامل

Full three-dimensional direction-dependent X-ray scattering tomography

Small-angle X-ray scattering (SAXS) detects the angular-dependent, coherently scattered X-ray photons, which provide improved contrast among different types of tissues or materials in medical diagnosis and material characterizations. By combining SAXS with computed tomography (CT), coherent scattering computed tomography (CSCT) enables the detection of spatially-resolved, material-specific scat...

متن کامل

Small angle X-ray scattering study on Lingula unguis shell.

Lingula unguis shell yields a diffuse small angle X-ray scattering which is caused mainly by the scattering from particles of apatite. In this study, the distribution of particles smaller than 500A was analyzed using the small angle X-ray scattering technique. The non-linear Guinier plot indicates that the shell contains various sizes of apatite particles ranging about 20-460A. The small granul...

متن کامل

X-Ray Diffuse Scattering

In this research program, modern x-ray scattering techniques are used to study the structures and phase transitions in novel states of condensed matter. We have two principal experimental facilities. At M.I.T. we have three high-resolution computer controlled x-ray spectrometers using either a conventional or high intensity rotating anode x-ray generator. The angular resolution can be made as f...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 1961

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.kj00001366016