STUDY ON ULTIMATE SHEAR STRENGTH OF PRE-STRESSED HIGH-STRENGTH CONCRETE PILE UNDER TENSILE OR LOW COMPRESSION AXIAL FORCE

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Strength Concrete Columns under Axial Compression Load: Hybrid Confinement Efficiency of High Strength Transverse Reinforcement and Steel Fibers

Addition of steel fibers to high strength concrete (HSC) improves its post-peak behavior and energy absorbing capability, which can be described well in term of toughness. This paper attempts to obtain both analytically and experimentally the efficiency of steel fibers in HSC columns with hybrid confinement of transverse reinforcement and steel fibers. Toughness ratio (TR) to quantify the confi...

متن کامل

Ultimate Strength and Failure Mechanism of Resistance Spot Weld Subjected to Tensile, Shear, or Combined Tensile/Shear Loads

Strength tests were performed to reveal the failure mechanisms of spot weld in lap-shear and cross tension test samples. It is shown the while the lap-shear (cross tension) sample is subjected to shear (normal) load at the structural level the failure mechanism at the spot weld is tensile (shear) mode at the materials level. Based on the observed failure mechanism, stress distribution is assume...

متن کامل

Ultimate tensile strength of tooth structures.

OBJECTIVE This study determined the ultimate tensile strength (UTS) of enamel (E), dentin (D) and dentin-enamel junction (DEJ) using the microtensile technique. It was hypothesized that the UTS of dental structures varies according to location and nature. METHODS Intact occlusal enamel surfaces from extracted human third molars were etched with 37% phosphoric acid and bonded with a one-bottle...

متن کامل

Push-out tests on shear studs in high strength concrete

A lot of push-out tests of shear studs embedded in normal strength concrete were conducted. So current design code methods of the shear studs are based on the test results of studs embedded in normal strength concrete. It also appeared that the strength of connector and the concrete strength are the main factors affecting the behavior of shear connections. But push-out test data of studs embedd...

متن کامل

Experimental and Numerical Study on Tensile Strength of Concrete under Different Strain Rates

The dynamic characterization of concrete is fundamental to understand the material behavior in case of heavy earthquakes and dynamic events. The implementation of material constitutive law is of capital importance for the numerical simulation of the dynamic processes as those caused by earthquakes. Splitting tensile concrete specimens were tested at strain rates of 10(-7) s(-1) to 10(-4) s(-1) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Japan Society of Civil Engineers, Ser. A1 (Structural Engineering & Earthquake Engineering (SE/EE))

سال: 2017

ISSN: 2185-4653

DOI: 10.2208/jscejseee.73.259