Study on Wind Vibration Coefficient Chang Rule of Cup Type Transmission tower Considered Abrupt Change in Stiffness
نویسندگان
چکیده
منابع مشابه
Study on Wind Vibration Coefficient Chang Rule of Cup Type Transmis- sion tower Considered Abrupt Change in Stiffness
Abstract: Wind load is the key and sensitive for tower structure but national standards tend to think that level stiffness change of cup type transmission tower is uniform along the height. The structure stiffness change of cup type transmission tower was simulated innovatively and found its nonuniformity. The result shows that the structural stiffness uniformly changes along the height when th...
متن کاملWind-induced Vibration Optimal Control for Long Span Transmission Tower-line System
In this paper, tuned mass dampers with optimal parameters for long span transmission tower-line system are investigated. Equations of motion for a structure-TMD system are derived, and the parameters of TMD, stiffness and damping are optimized, respectively. According to a real project, three-dimensional finite element models of both transmission tower and transmission tower-line system are cre...
متن کاملThe Wind-Induced Vibration Response for Tower Crane Based on Virtual Excitation Method
The Dynamics characteristic of Tower Crane is complicated under the wind excitation which complicates the wind-induced vibration response analysis. The random wind-induced response analysis of tower crane is presented based on finite element method and Virtual Excitation Method. The pulsating wind loads are changed into multiple-point correlation stationary excitation. This papers uses Davenpor...
متن کاملPitch Control for Eliminating Tower Vibration Events on Active Stall Wind Turbines
Negative aerodynamic damping causes tower vibrations on turbines with stall rotors. Under certain conditions, these vibrations may rise to a level that causes a shutdown. Active stall turbines have a pitch system, and the objective of the work was to develop pitch control algorithms which would minimise the probability of tower vibrations rising to the shutdown level. The results of a root caus...
متن کاملExperimental and numerical study of natural ventilation in four-sided wind tower traps
In the past, wind towers were applied as the main architectural part of building construction in the desert areas of Iran. These almost high structures were used as cooling load suppliers at residential buildings. In the present study, the effect of symmetric four-sided wind tower in flow induction to the bottom space has been analysed by using a wind tunnel and numerical simulations. In the nu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Open Automation and Control Systems Journal
سال: 2014
ISSN: 1874-4443
DOI: 10.2174/1874444301406011515