STUDYING CRACK RESISTANCE OF REINFORCED-CONCRETE − FIBRE-GLASS COMPOSITE PRESSURE PIPES FOR MICROTUNNELING

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glass Fibre Reinforced Concrete

Glass Fibre Reinforced Concrete is recent introduction in the field of concrete technology. The present day world is witnessing the construction of very challenging and difficult Civil Engineering Structures. Concrete being the most important and widely used material is called upon to possess very high strength and sufficient workability properties. Concrete the most widely used consrtuction ma...

متن کامل

Stress-strain Response Modelling of Glass Fibre Reinforced Epoxy Composite Pipes under Multiaxial Loadings

This paper presents the modelling of stress strain response of glass fibre reinforced epoxy (GRE) composite pipes subjected to multiaxial loadings at room temperature (RT). This particular modelling work was developed to predict the non-linear stress strain response caused by the fatigue cyclic and static loading in the multiaxial ultimate elastic wall stress (UEWS) tests by considering the eff...

متن کامل

Influence of Fibre Content on Crack Propagation Rate in Fibre-Reinforced Concrete Beams

Experimental study on the influence of fibre content on crack behaviour and propagation in synthetic-fibre reinforced beams has been reported in this paper. The tensile behaviour of metallic fibre concrete is evaluated in terms of residual flexural tensile strength values determined from the load-crack mouth opening displacement curve or load-deflection curve obtained by applying a centre-point...

متن کامل

Ductility Performance of Hybrid Fibre Reinforced Concrete

This study presents a study on the ductility performance of hybrid fibre reinforced concrete. The influence of fibre content on the ductility performance of hybrid fibre reinforced concrete specimens having different fibre volume fractions was investigated. The parameters of investigation included modulus of rupture, ultimate load, service load, ultimate and service load deflection, crack width...

متن کامل

Risk-based Replacement Strategies for Deteriorating Reinforced Concrete Pipes

Water distribution networks comprised of underground reinforced concrete pipes deteriorate with time due to environmental conditions, such as chloride-induced corrosion and differential soil movements [1]. If the pipes in these networks are not periodically replaced, they will eventually fail. Strategies for replacement for these pipes depend on 1) the risks associated with failure of a water d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Problemy sovremennogo betona i zhelezobetona

سال: 2019

ISSN: 2076-6033

DOI: 10.35579/2076-6033-2019-11-06