Subcuticular Suture Technique: Alternative to Frost Suture to Prevent Ectropion After Transcutaneous Incision of Lower Eyelid
نویسندگان
چکیده
منابع مشابه
Spontaneous complete migration of suture material after subcuticular continuous suture in cesarean section: a case report
BACKGROUND Skin closure during cesarean section is often performed with subcuticular running sutures by using a nonabsorbable suture material. However, this material has the risk of incomplete removal after wound healing and can migrate to other sites in rare cases. CASE PRESENTATION A 34-year-old Korean woman who had undergone a cesarean section 5 months prior presented with a fine, blue obj...
متن کاملComparison of Subcuticular Suture Materials in Cesarean Skin Closure
Aim. Comparison of the rate of wound complications, pain, and patient satisfaction based on used subcuticular suture material. Methods. A total of 250 consecutive women undergoing primary and repeat cesarean section with low transverse incision were prospectively included. The primary outcome was wound complication rate including infection, dehiscence, hematoma, and hypertrophic scar formation ...
متن کاملCosmetic outcomes of cesarean section scar; subcuticular suture versus intradermal buried suture
Objective The objective of the study was to compare cosmetic outcomes and overall satisfaction rate of cesarean section scar between conventional subcuticular suture and intradermal buried vertical mattress. Methods Patients were enrolled to the study by chart review. A scar assessment was obtained retrospectively through a telephone survey. The patient component of the patient and observer s...
متن کاملBlepharoplasty with a Buried Double Twisted Suture Technique to Correct Upper Eyelid Epiblepharon.
BACKGROUND The authors evaluated the clinical efficacy of blepharoplasty using a newly developed, buried double twisted suture (BDTS) technique to correct upper eyelid epiblepharon. METHODS This retrospective study was conducted from October 2013 to July 2015 at the Oculoplastic Clinic, Bundang CHA Medical Center, CHA University, Seongnam, Korea. A total of 122 eyes from 61 patients with uppe...
متن کاملSutureless skin closure for pacemaker implantation: comparison with subcuticular suture.
In 51 patients undergoing pacemaker implantation a trial was carried out to compare the results of sutureless skin closure using a new product (Op-Site skin closures) with skin closure using a continuous subcuticular absorbable (Dexon) suture. Incisions closed with Op-Site skin closures healed as well as those closed with subcuticular suture but were associated with less frequent and less exten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Maxillofacial and Oral Surgery
سال: 2017
ISSN: 0972-8279,0974-942X
DOI: 10.1007/s12663-017-1005-z