Subspace-based interference removal methods for a multichannel biomagnetic sensor array

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multichannel Squid Biomagnetic Systems

The field of biomagnetism advanced considerably since the first recordings of magnetic fields of the human heart in 1963 and of the human brain in 1968. Since the introduction of whole-cortex magnetoencephalography (MEG) systems in 1992, the number of installed channels has dramatically increased, and the magnetic evaluation of the human brain has been gradually finding its place in clinical wo...

متن کامل

A Subspace-Tracking Approach to Interference Nulling for Phased Array-Based Radio Telescopes

Several next-generation radio telescopes, now in the planning stages, are based on phased-array technology. One reason for this is to make use of adaptive nulling techniques to combat radio frequency interference, which is a growing problem for radio astronomy. This paper presents a low-complexity approach to interference nulling which is suitable for use in such systems. The approach uses subs...

متن کامل

Double Relaxation Oscillation SQUID Systems for Biomagnetic Multichannel Measurements

Multichannel superconducting quantum interference device (SQUID) systems based on double relaxation oscillation SQUIDs (DROS) were developed for measuring magnetocardiography (MCG) and magnetoencephalography (MEG) signals. Since DROS provides large fluxto-voltage transfer coefficients, about 10 times larger than the DC SQUIDs, direct readout of the SQUID output was possible using compact roomte...

متن کامل

A Low-Complexity Nyström-Based Algorithm for Array Subspace Estimation

Subspace-based methods rely on singular value decomposition (SVD) of the sample covariance matrix (SCM) to compute the array signal or noise subspace. For large array, triditional subspace-based algorithms inevitably lead to intensive computational complexity due to both calculating SCM and performing SVD of SCM. To circumvent this problem, a NyströmBased algorithm for array subspace estimation...

متن کامل

Multichannel monolithic quartz crystal microbalance gas sensor array.

Multichannel Monolithic Quartz Crystal Microbalance (MQCM), in which an array of electrodes is fabricated on a monolithic quartz wafer, is a very attractive approach for miniaturization using Micro-Electro-Mechanical Systems(MEMS) technology for high throughput chemical or biological sensor systems. In this paper, we demonstrate and validate a monolithic QCM sensor array for gas detections. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Neural Engineering

سال: 2017

ISSN: 1741-2560,1741-2552

DOI: 10.1088/1741-2552/aa7693