Subsynchronous instability of HVDC transmission system.
نویسندگان
چکیده
منابع مشابه
Damping of Subsynchronous Resonance Using a Vsc-hvdc Link
A possible detrimental effect of onshore series compensation in the GB grid is the appearance of subsynchronous resonance (SSR). In this paper, a control scheme for a VSC-HVDC link capable of damping subsynchronous oscillations is proposed in order to effectively counteract the potential damage caused by SSR in steam turbines. The VSC-HVDC link has been modelled to maintain its primary function...
متن کاملReliability Improvement Strategies for HVDC Transmission System
This paper analyses reliability data of HVDC systems of Southern China Power Grid. The weak links of HVDC systems’ operational reliability are DC control and protection, valve hall and valve cooling system and transmission lines. Some improvement measures and HVDC system reliability technology are proposed in this paper.
متن کاملHVDC Transmission with STATCOM
Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these case, the consideration was the converter ...
متن کاملPower limitations of the HVDC Transmission Power System
The scope of the presented paper is concentrated on two terminal HVDC transmission system. The intention of the paper is to present a precise insight into the limitations of the transmitted power of a HVDC system incorporated in real AC power system. The paper demonstrates the impacts of the combined AC/DC system model parameters on the transmitted power through the DC link. Also, in this paper...
متن کاملSubsynchronous Torsional Interaction of Wind Farms with FSIG Wind Turbines Connected to LCC-HVDC Lines
High-voltage direct current (HVDC) lines with line-commutated converter (LCC) are being increasingly employed to transmit bulk wind power over long distance. However, this may cause the sub-synchronous torsional interaction (SSTI) between the wind farms and the LCC-HVDC system. The SSTI characteristics of wind farms with fixed-speed induction generator (FSIG) wind turbines connected to LCC-HVDC...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1985
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1972.105.323