Successful percutaneous retrieval of a micra transcatheter pacing system at 8 weeks after implantation
نویسندگان
چکیده
منابع مشابه
Retrieval of Medtronic Micra Transcatheter Pacing System after tether removal.
We implanted a Medtronic Micra Transcatheter Pacing System (TPS) using standard technique, but after cutting the tether, a slight resistance was felt when the tether was pulled back. Subsequently, the electrical properties of the system were unacceptable. In order to retrieve the TPS, a 3 F snare with a 10–25 mm loop can be loaded into the delivery system. However, this snare was not available....
متن کاملExternal electrical cardioversion of persistent atrial fibrillation in a patient with a Micra™ Transcatheter Pacing System
We report a case of a 85-year old woman with a preexisting Transcatheter Pacing System (TPS) (Micra™ VR, Fa. Medtronic, Inc., Minneapolis, MN, USA) undergoing several external electrical cardioversions (CV) for symptomatic persistent atrial fibrillation (persAF). Due to bradycardia in the setting of atrial fibrillation a right apical TPS implantation was performed earlier. Four weeks prior to p...
متن کاملExtraction of a Micra Transcatheter Pacing System: First-in-human experience
Clinical trials investigating the safety and effectiveness of transcatheter leadless pacemakers in humans are ongoing. These devices offer the benefits of cardiac pacing with the potential for a significant decrease in many of the risks associated with conventional pacing systems, including hematoma formation, pneumothorax, lead-related complications, and vascular obstruction. Human evaluation ...
متن کاملSuccessful percutaneous coronary intervention after transcatheter aortic valve implantation with CoreValve bioprosthesis
We present a case of an 84-year-old male patient who was admitted to our department due to recurrent angina 17 months after transcatheter aortic valve implantation (TAVI) with a 29 mm CoreValve bioprosthesis (Figure 1). Symptoms were increasing in the past several weeks, and on admission the patient was in Canadian Cardiovascular Society class 3. His past medical history included hypertension a...
متن کاملEarly performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study
AIMS Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker. METHODS AND RESULTS Patients having Class I or II indication for VVI pacing underwent implanta...