Successful percutaneous retrieval of unusually knotted temporary pacemaker lead
نویسندگان
چکیده
منابع مشابه
Percutaneous Retrieval of a Knotted Provisional Pacemaker Using Proximal Electrode Cut off and Distal End Snaring
Although provisional pacemaker implantation can safely be done in many cases, a rare complication such as knotted electrode has been described, especially when the procedure is performed without fluoroscopy guidance. We describe a case of knot creation in a provisional pacemaker which was successfully retrieved using a snare after cutting the electrode proximally.
متن کاملA rare complication after pacemaker implantation: unusually shaped lead coil.
31:184–194. 6. Wiviott SD, Antman EM, Winters KJ, Weerakkody G, Murphy SA, Behounek BD, Carney RJ, Lazzam C, McKay RG, McCabe CH, Braunwald E; JUMBO-TIMI 26 Investigators. Randomized comparison of prasugrel (CS-747, LY640315), a novel thienopyridine P2Y12 antagonist, with clopidogrel in percutaneous coronary intervention: results of the joint utilization of medications to block platelets optima...
متن کاملSuccessful percutaneous extraction of pacemaker leads with a novel (VascoExtor) pacing lead removal system.
A new pacing lead extraction system (VascoExtor, VascoMed, Germany) with a universally applicable locking stylet was used over a period of 12 months to extract 25 permanent pacemaker leads (mean implantation time 3.9 +/- 3.8 years) in 16 patients who had pacemaker infection (n = 13), lead dysfunction (n = 2), or before an automatic defibrillator implant (n = 1). With use of this system, we were...
متن کاملSuccessful percutaneous repositioning of a dislodged atrial pacemaker lead with a deflectable catheter.
A 67-year-old male patient with ischemic dilated cardiomyopathy underwent implantation of an implantable cardioverter-defibrillator with cardiac resynchronization therapy about one month ago. The implantation process was successful and the patient was discharged in good condition. At the routine first month follow-up, pacemaker analysis revealed that there was no atrial pacing and sensing, alth...
متن کاملSuccessful percutaneous retrieval of a leadless pacemaker due to an acute rise in pacing threshold
Leadless cardiac pacemakers (LCP) have become available recently. Both its acute and long-term performance in a large population of patients remain to be tested. Subacute rise in pacing threshold has been reported as an uncommon complication. On the other hand, the retrieval technique for LCP with passive fixation mechanism has not been previously described in details. Herein we report a newly ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Pacing and Electrophysiology Journal
سال: 2018
ISSN: 0972-6292
DOI: 10.1016/j.ipej.2018.02.004