Successful percutaneous retrieval of unusually knotted temporary pacemaker lead

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Retrieval of a Knotted Provisional Pacemaker Using Proximal Electrode Cut off and Distal End Snaring

Although provisional pacemaker implantation can safely be done in many cases, a rare complication such as knotted electrode has been described, especially when the procedure is performed without fluoroscopy guidance. We describe a case of knot creation in a provisional pacemaker which was successfully retrieved using a snare after cutting the electrode proximally.

متن کامل

A rare complication after pacemaker implantation: unusually shaped lead coil.

31:184–194. 6. Wiviott SD, Antman EM, Winters KJ, Weerakkody G, Murphy SA, Behounek BD, Carney RJ, Lazzam C, McKay RG, McCabe CH, Braunwald E; JUMBO-TIMI 26 Investigators. Randomized comparison of prasugrel (CS-747, LY640315), a novel thienopyridine P2Y12 antagonist, with clopidogrel in percutaneous coronary intervention: results of the joint utilization of medications to block platelets optima...

متن کامل

Successful percutaneous extraction of pacemaker leads with a novel (VascoExtor) pacing lead removal system.

A new pacing lead extraction system (VascoExtor, VascoMed, Germany) with a universally applicable locking stylet was used over a period of 12 months to extract 25 permanent pacemaker leads (mean implantation time 3.9 +/- 3.8 years) in 16 patients who had pacemaker infection (n = 13), lead dysfunction (n = 2), or before an automatic defibrillator implant (n = 1). With use of this system, we were...

متن کامل

Successful percutaneous repositioning of a dislodged atrial pacemaker lead with a deflectable catheter.

A 67-year-old male patient with ischemic dilated cardiomyopathy underwent implantation of an implantable cardioverter-defibrillator with cardiac resynchronization therapy about one month ago. The implantation process was successful and the patient was discharged in good condition. At the routine first month follow-up, pacemaker analysis revealed that there was no atrial pacing and sensing, alth...

متن کامل

Successful percutaneous retrieval of a leadless pacemaker due to an acute rise in pacing threshold

Leadless cardiac pacemakers (LCP) have become available recently. Both its acute and long-term performance in a large population of patients remain to be tested. Subacute rise in pacing threshold has been reported as an uncommon complication. On the other hand, the retrieval technique for LCP with passive fixation mechanism has not been previously described in details. Herein we report a newly ...