Successful Use of the MYNXGRIP Closure Device during Repeated Transbrachial Percutaneous Peripheral Intervention
نویسندگان
چکیده
منابع مشابه
Successful Use of the MYNXGRIP Closure Device during Repeated Transbrachial Percutaneous Peripheral Intervention
The use of closure devices after transbrachial arterial puncture is still controversial. Here we report on a case where the MYNXGRIP (AccessClosure Inc., Santa Clara, CA, USA) could be used successfully in a patient, who underwent percutaneous peripheral arterial intervention twice via transbrachial access.
متن کاملSuccessful percutaneous coronary intervention during cardiac arrest with use of an automated chest compression device: a case report
Ventricular tachycardia or fibrillation (VT/VF) in patients with ST-elevation myocardial infarction (STEMI) is associated with poor prognosis. Performing manual chest compressions is a serious obstacle for treatment with percutaneous coronary intervention (PCI). Here we introduce a case with refractory VT/VF where the patient was successfully treated with an automated chest compression device, ...
متن کاملSuccessful management of dislodged stents during percutaneous coronary intervention.
Stent dislodgement is a very rare but recognized and potentially serious complication of percutaneous coronary intervention (PCI). This case series describe the incidence and etiology of such cases at National Institute of Cardiovascular Diseases, Karachi during the year 2008 and the method of treatment of this complication.
متن کاملA cost-minimization analysis of the angio-seal vascular closure device following percutaneous coronary intervention.
The Angio-Seal vascular closure device has been shown to be safe and effective in decreasing the time to hemostasis after percutaneous coronary intervention (PCI). The health economic implications of routinely using Angio-Seal after PCI have not been explored. We performed a cost-minimization analysis comparing routine Angio-Seal use after PCI with mechanical compression using a decision analyt...
متن کاملSuccessful percutaneous closure of a residual atrial septal defect due to device failure.
A 39-year-old woman underwent uneventful percutaneous occlusion of an ostium secundum atrial septal defect (ASD) with a 22 mm Ultrasept ASD Occluder®. Transesophageal echocardiography (TEE) performed two years after implantation revealed a de novo residual left-to-right shunt through the correctly implanted device. Three-dimensional transesophageal echocardiography (3D TEE) further clarified th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Case Reports in Vascular Medicine
سال: 2015
ISSN: 2090-6986,2090-6994
DOI: 10.1155/2015/346506