ABSTRACT Blade failure is a common problem of a steam turbine and it’s failure in-service results in safety risks, repair cost and non operational revenue losses. Thus, the reliability of these blades is very important for the successful operation of a steam turbine. Dynamic analysis of a steam turbine blade in computational environment is carried out in the present work. In order to gain physi...
متن کاملTidal Steam Turbine Blade Fault Diagnosis Using Time-Frequency Analyses
Tidal Stream Turbines are developing renewable energy devices, for which proof of concept commercial devices are been deployed. The optimisation of such devices is supported by research activities. Operation within selected marine environments will lead to extreme dynamic loading and other problems. Further, such environments emphasise the need for condition monitoring and prognostics to suppor...
متن کاملWind Turbine Blade Design
A detailed review of the current state-of-art for wind turbine blade design is presented, including theoretical maximum efficiency, propulsion, practical efficiency, HAWT blade design, and blade loads. The review provides a complete picture of wind turbine blade design and shows the dominance of modern turbines almost exclusive use of horizontal axis rotors. The aerodynamic design principles fo...
متن کاملMetallurgical fatigue failure analysis of the brazed steam turbine blade
In this paper, failure mechanism of a 17th stage blade of an 82.5 MW steam turbine that caused damage to the internal turbine compartment and the adjacent blade equipment has been studied. In order to determine the cause of failure and prevent similar events, various metallurgical and mechanical investigations including chemical composition analysis, metallography and microstructural analysis, ...
متن کاملMetallurgical fatigue failure analysis of the brazed steam turbine blade
In this paper, failure mechanism of a 17th stage blade of an 82.5 MW steam turbine that caused damage to the internal turbine compartment and the adjacent blade equipment has been studied. In order to determine the cause of failure and prevent similar events, various metallurgical and mechanical investigations including chemical composition analysis, metallography and microstructural analysis, ...