Supershort avalanche electron beams and x-ray in high-pressure nanosecond discharges
نویسندگان
چکیده
منابع مشابه
Electric field measurement in repetitively pulsed nanosecond discharges in a high pressure hydrogen environment
Electric fields of repetitively pulsed nanosecond discharges have been measured from electric-field induced Raman scattering by hydrogen molecules. Especially the temporal evolution of the electric field spatial distribution was recorded. With a high-speed optical emission intensity analysis, it has been found that most ionization events take place within a very short period during an ionizatio...
متن کاملX-ray and TeV Gamma-Ray Emission from Parallel Electron-Positron or Electron-Proton Beams in BL Lac Objects
In this paper we discuss models of the X-rays and TeV γ-ray emission from BL Lac objects based on parallel electron-positron or electron-proton beams that form close to the central black hole owing to the strong electric fields generated by the accretion disk and possibly also by the black hole itself. Fitting the energy spectrum of the BL Lac object Mrk 501, we obtain tight constraints on the ...
متن کاملHigh pressure X-ray studies at NSLS
The National Synchrotron Light Source offers the COMPRES community a considerable opportunity for x-ray studies using the superconducting wiggler at X17. This beamline has a steep history of high pressure innovations including diamond anvil studies and large volume studies. The superconducting wiggler continues to provide an x-ray source that is competitive with third generation sources for x-r...
متن کاملDiamond Monochromator for High Heat Flux Synchrotron X-ray Beams
2 Single crystal silicon has been the material of choice for x-ray monochromators for the past several decades. However, the need for suitable monochromators to handle the high heat load of the next generation synchrotron x-ray beams on the one hand and the rapid and on-going advances in synthetic diamond technology on the other make a compelling case for the consideration of a diamond monochro...
متن کاملDifference in the relative response of the alanine dosimeter to megavoltage x-ray and electron beams.
In order to increase the usefulness of the alanine dosimeter as a tool for quality assurance measurements in radiotherapy using MV x-rays, the response with respect to the dose to water needs to be known accurately. This quantity is determined experimentally relative to (60)Co for 4, 6, 8, 10, 15 and 25 MV x-rays from two clinical accelerators. For the calibration, kQ factors for ionization cha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2008
ISSN: 1742-6596
DOI: 10.1088/1742-6596/133/1/012021