Surge Protection Device for Ex Application
نویسندگان
چکیده
منابع مشابه
Novel Intrinsic Conducting Polymer Current Limiting Device (CLD) for Surge Protection
In the past many uneconomic solutions for limitation and interruption of short-circuit currents in low power applications have been introduced, especially polymer switch based on the positive temperature coefficient of resistance (PCTR) concept. However there are many limitations in the active material, which consists of conductive fillers. This paper presents a significantly improved and simpl...
متن کاملSCR-Based Advanced ESD Protection Device for Low Voltage Application
This paper proposed a silicon controller rectifier (SCR) based ESD protection device to protect low voltage ESD for integrated circuit. The proposed ESD protection device has low trigger voltage and high holding voltage compared with conventional SCR-based ESD protection devices. The proposed ESD protection circuit is verified and compared by TCAD simulation. This paper verified effective low v...
متن کاملSurge Protection of End-User Equipment
This document is included in the Annex of Part 7 as historical background of a well-intentioned task that was completed at too slow a pace, missing its target date for serving as a reference for other in-process IEC standards projects concerned with low-voltage surge-protective devices. For the sake of historical accuracy and perspective, the document is presented here in its draft form, includ...
متن کاملA circuit simplification for AC power supply surge protection devices
As far as the design of SPDs is concerned, the need exists for simplifying its circuit structure in fulfilment of the prerequisite condition of protective reliability. The circuit simplification for SPDs is of benefit to lower the cost of manufacture and reduce the size of chassis. Considering that the traditional SPD that has been extensively used on single-phase AC power supply lines requires...
متن کاملEx vivo evaluation of a Taylor-Couette flow, immobilized heparinase I device for clinical application.
Efficient and safe heparin anticoagulation has remained a problem for continuous renal replacement therapies and intermittent hemodialysis for patients with acute renal failure. To make heparin therapy safer for the patient with acute renal failure at high risk of bleeding, we have proposed regional heparinization of the circuit via an immobilized heparinase I filter. This study tested a device...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Science, Technology and Engineering Systems Journal
سال: 2020
ISSN: 2415-6698,2415-6698
DOI: 10.25046/aj050692