Symmetrical Pole Placement Method-Based Unity Proportional Gain Resonant and Gain Scheduled Proportional (PR-P) Controller With Harmonic Compensator for Single Phase Grid-Connected PV Inverters
نویسندگان
چکیده
In this paper, a symmetrical pole placement Method-based Unity Proportional Gain Resonant and Scheduled (PR-P) Controller is presented. The proposed PR-P controller resolved the issues that are tracking repeating control input signal with zero steady-state mitigating of 3rd order harmonic component injected into grid associated use PI for single-phase PV systems. Additionally, has overcome drawbacks frequency detuning in increase magnitude odd number harmonics system constitute common concerns implementation conventional PR developed as an alternative to controller. Moreover, application unprecedented design process based on changing notch filter dynamics around resonant overcomes limitations essentially complexity dependency precisely modelled various controllers such Adaptive, Predictive Hysteresis connected power generation was validated employing Photovoltaic emulator (PVE) consisting DC-DC Buck converter, maximum point (MPPT) algorithm full-bridge inverter designed using MATLAB/Simulink platform. Details controller, simulations, analysis test results were presented paper.
منابع مشابه
Current mode Controller Design for Single Phase grid connected Inverter Using Proportional Resonant Control Strategy
This paper presents the design of controller based on proportional resonant strategy for single-phase grid connected inverter. The control design is carried out using Sisotool, which is provided in Matlab. By using this tool, users can examine the effects of changing the gain control values to system's transient response and stability, simultaneously. Hence, simplify and speed up the control de...
متن کاملReview on Single-phase PV Inverters for Grid-connected Applications
In this paper, a review of PV inverters is reported based on converter characteristics as the number of energy processing stages, the presence of a transformer (high-frequency or 50Hz transformer), and the adopted configuration of the PV field. In particular, the considered solutions have been evaluated depending on efficiency, input current ripple and life-time of the capacitors coupling with ...
متن کاملAn Adaptive Hystersis Controller for Single-Phase Grid- Connected PV Central Inverters
An adaptive hysteresis current controller for single-phase single-stage photovoltaic central inverters is presented. The designed controller is able to eliminate harmonic distortion and to control switching frequency and to inject the current into power grid with good power quality. The simulation model of the system is developed in SIMULINK/MATLAB environment. The controller is found effective...
متن کاملDesign of Grid connected Photovoltaic Inverter with Resonant Harmonic Compensator
The reduction of high harmonic content in the grid side current is achieved by different harmonic compensating techniques. In order to accomplish it, selective harmonic compensation is carried out in grid-connected photovoltaic inverters by means of resonant harmonic compensators. The harmonic compensator shown in this paper is lead lag compensator. This paper shows a systematic design procedur...
متن کاملPR Current Control with Harmonic Compensation in Grid Connected PV Inverters
This paper presents a study on Proportional Resonant (PR) current control with additional PR harmonic compensators for Grid Connected Photovoltaic (PV) Inverters. Both simulation and experimental results will be presented. Testing was carried out on a 3kW Grid-Connected PV Inverter which was designed and constructed for this research. Keywords—Inverters, Proportional-Resonant Controllers, Harmo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2021
ISSN: ['2169-3536']
DOI: https://doi.org/10.1109/access.2021.3092827