Symphysiodesis with a new compression plate
نویسندگان
چکیده
منابع مشابه
Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse
Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was obs...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملResults of ulnar shortening osteotomy with a new plate compression system.
PURPOSE The gold standard for treatment of ulnar impaction has become ulnar shortening osteotomy. Previous reports in the literature have shown not only good results with relief of ulnar-sided wrist pain but also significant nonunion rates and painful hardware necessitating further surgery and potentially, metal removal. The purpose of this paper is to review the success rate of ulnar shortenin...
متن کاملPlate fixation of clavicle fractures: a comparative study between Reconstruction Plate and Dynamic Compression Plate.
This study aimed at comparing the results of clavicular fracture fixation with AO Reconstruction (Recon) plate and Dynamic Compression Plate (DCP). The case notes of 39 patients with 40 acute and chronic clavicular fractures were retrospectively reviewed. The indications for fixation for acute cases comprised open fractures, the presence of sufficient skin tenting to risk skin integrity, neurov...
متن کاملa new type-ii fuzzy logic based controller for non-linear dynamical systems with application to 3-psp parallel robot
abstract type-ii fuzzy logic has shown its superiority over traditional fuzzy logic when dealing with uncertainty. type-ii fuzzy logic controllers are however newer and more promising approaches that have been recently applied to various fields due to their significant contribution especially when the noise (as an important instance of uncertainty) emerges. during the design of type- i fuz...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Orthopaedica Scandinavica
سال: 1984
ISSN: 0001-6470
DOI: 10.3109/17453678408992364