منابع مشابه

Evaluation of pleural and ascitic fluid analysis on the Sysmex XE-5000 hematology analyzer

Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000 hematology analyzer in the analysis of pleural and ascitic fluids in the laboratory routine of...

متن کامل

Do the flags related to immature granulocytes reported by the Sysmex XE-5000 warrant a microscopic slide review?

OBJECTIVES The Sysmex XE-5000 instruments (Sysmex, Kobe, Japan) count immature granulocytes (IGs) and use the "Imm Gran?" flag to signal unreliable results. This study investigated the usefulness of the "Imm Gran?" flag and the analytical and diagnostic performance of the IG measurements in a side-by-side evaluation. METHODS In total, 408 samples were analyzed on three XE-5000 instruments. Th...

متن کامل

Potential utility of the new Sysmex XE 5000 red blood cell extended parameters in the study of disorders of iron metabolism.

BACKGROUND New erythrocyte parameters are reported by the Sysmex XE 5000 analyzer. This instrument measures the hemoglobin (Hb) content of individual red cells, calculates the percentage of hypochromic red cells (%Hypo He) and the percentage of hyperchromic red cells (%Hyper He) and quantifies the proportion of marginally sized erythrocytes (%Micro R and %Macro R). The goals of the study were t...

متن کامل

Immature granulocyte measurement using the Sysmex XE-2100. Relationship to infection and sepsis.

We determined the usefulness of immature granulocyte measurement as a predictor of infection or positive blood culture and compared the results with total WBC count and absolute neutrophil count (ANC). Blood samples from 102 infected and 69 noninfected patients were analyzed using the Sysmex XE-2100 automated blood cell counter (Sysmex, Kobe, Japan). The percentage of immature granulocytes was ...

متن کامل

New Red Cell Parameters on the Sysmex XE-2100 as Potential Markers of Functional Iron Deficiency

The ideal approach to monitor the haematological response of patients with the anaemia associated with chronic renal failure during erythropoietin therapy is controversial. The reticulocyte haemoglobin content (CHr) and percentage hypochromic red cells (% Hypo) may be used as sensitive and specific indicators of functional iron deficiency in clinical situations with otherwise normal red cell in...