T1 inversion recovery pulse sequence: could it replace T1 spin echo sequence in neuroimaging by improving tissue contrast?

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR T1-weighted inversion recovery imaging in detecting brain metastases: could it replace T1-weighted spin-echo imaging?

BACKGROUND AND PURPOSE T1-weighted inversion recovery (T1IR) imaging demonstrates higher brain tissue contrast and is more sensitive to contrast enhancement than T1-weighted spin-echo (T1SE) imaging. However, the effectiveness of the 2 imaging sequences in detecting brain metastases has not been studied. The objective of this report was to determine which sequence should be used for detecting b...

متن کامل

comparison of maximum signal intensity of magnevist contrast agent in modified t1 weighted spin echo, t1 weighted fast spin echo and t1 weighted gradient echo sequences

background:  nowadays mri examinations have been widely used in clinical applications for many diagnoses. the use of contrast agent in mri improves lesion detection and characterization and causes more accurate diagnosis.  objectives: the aim of this study was comparing to optimal dose of magnevist contrast agent in modified t1w se (spin echo), t1w fse (fast spin echo) and t1w gre (gradient ech...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

comparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences

conclusion using standard imaging parameters, each mri sequence reaches its maximum si in a specific contrast concentration, which is highest in se and least in ir in a comparison between se, fse and ir sequences. results this study shows that maximum si will appear at different ranges in different sequences. the maximum si can be seen at concentrations of 5.95, 4.96 and 3.98mmol/l for se, fse ...

متن کامل

Rapid T1 Determination with Optimized Inversion Recovery Sequence

Introduction: There is continuing interest in rapid quantitative measurements of spin-lattice relaxation time (T1). Conventionally, an inversionrecovery (IR) sequence is used to determine T1, with logarithmic spacing of inversion recovery times (ti), a long pre-delays (td), and with data fitted to a single-exponential equation. Spin-echo (SE) or fast-spin-echo (FSE) techniques may be applied fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Egyptian Journal of Radiology and Nuclear Medicine

سال: 2019

ISSN: 2090-4762

DOI: 10.1186/s43055-019-0028-5