Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

PURPOSE The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). METHODS We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated ...

متن کامل

Transcatheter aortic paravalvular leak closure using 3 Amplatzer Vascular Plug III devices in a child

Paravalvular leak (PVL) is usually related to disruption of prosthetic valve sewing ring sutures. Many previous reports have described transcatheter paravalvular leak closure in adult patients [1–4], but those describing such a procedure in children are scarce. A 16-year-old boy underwent an aortic valve replacement (AVR) with a stented bioprosthesis Hancock 23 mm due to combined aortic stenosi...

متن کامل

Clinical manifestations of heart failure abate with transcatheter aortic paravalvular leak closure using Amplatzer vascular plug II and III devices.

OBJECTIVES To evaluate the transcatheter paravalvular leak closure (TPVLC) aptitude to reduce manifestations of heart failure caused by aortic paravalvular leak (PVL). BACKGROUND TPVLC is a valuable alternative to reoperation. While technical feasibility of the method is well established, data on long-term clinical outcome are less abundant. METHODS We launched a prospective registry of pat...

متن کامل

Applications of the Amplatzer Vascular Plug 4.

The purpose of this study was to present our initial experience with the Amplatzer® Vascular Plug (AVP) 4 in various arterial environments. This material was designed for the embolization of peripheral small vessels using a diagnostic catheter. Herein, the following three procedures using the AVP 4 were described: hemodialysis fistula occlusion as a treatment for the steal pheno...

متن کامل

Paravalvular leak closure with the Amplatzer Vascular Plug III device: immediate and short-term results.

INTRODUCTION AND OBJECTIVES Percutaneous paravalvular leak closure is a complex procedure with varying success rates; the lack of closure devices specifically designed for this purpose has hampered this technique. The characteristics of the Amplatzer Vascular Plug III appear to be well suited for paravalvular leak closures; however, the available data are limited to case reports or small series...