TCTAP C-243 Percutaneous Retrieval of Migrated Atrial Septal Defect Occluder After Implantation of Device

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Extraction of an Embolized Atrial Septal Defect Occluder Device into Pulmonary Artery after Percutaneous Closure

An atrial septal defect is the most common type of congenital heart disease among adults. Surgical repair or percutaneous closure of the defect is the treatment options. Even though percutaneous closure seems to be less risky than surgical repair, it may result in fatal complications like device embolism, cardiac perforation and tamponade. Herein we report a case of the embolism of a device int...

متن کامل

Animal experimental implantation of an atrial septal defect occluder system.

OBJECTIVE To establish the implantation technique for the atrial septal defect occluder system (ASDOS) device in an experimental animal model and to determine long term mechanical stability of the device and its in vivo properties in terms of biocompatibility and tissue reaction. MATERIALS AND METHODS An atrial septal defect was created and the device implanted in 17 pigs (mean weight 30 kg)....

متن کامل

Percutaneous Retrieval of Embolized Amplatzer Septal Occluder after Treatment of Double Atrial Septal Defect: A Case Report

Embolization of the occlusion device after percutaneous closure of atrial septal defect (ASD) is a potential disastrous complication. The usual site of embolization is the right side of the heart including pulmonary artery, but the device embolization to the extracardiac aorta is extremely rare. Here, we report a successful percutaneous retrieval case of the embolized Amplatzer Septal Occluder ...

متن کامل

Percutaneous closure of a postoperative residual atrial septal defect with the Occlutech Figulla Occluder device.

A 67-year-old male patient with an eight-month history of operation for mitral valve repair and secundum atrial septal defect (ASD) presented with complaints of fatigue and shortness of breath. Transthoracic echocardiography showed a residual ASD resulting from separation of a pericardial patch. Qp/Qs rate was 3.2. The diameter of the residual defect measured by transesophageal echocardiography...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American College of Cardiology

سال: 2016

ISSN: 0735-1097

DOI: 10.1016/j.jacc.2016.03.461