TECHNICAL STUDIES ON HELICAL CT SYSTEMS : Performance Evaluation and clinical Use
نویسندگان
چکیده
منابع مشابه
Helical CT : Principles and Technical Considerations 1
. INTRODUCTION Helical computed tomography (CT) offers several technical advantages that have revolutionized body CT. Use of helical technology has improved established CT applications by the minimization of motion artifacts, the elimination of respiratory misregistration artifacts (1,2), and the production of overlapping images without additional x-ray exposure (3-5). New applications involvin...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملTECHNICAL PERFORMANCE OF SPINAL AND COMBINED SPINAL-EPIDURAL BLOCK Studies on equipment durability and clinical effects
Academic dissertation To be presented, by permission of the Medical Faculty of the University of Helsinki for public examination in the lecture hall of Töölö Hospital,
متن کاملeffect of bataine and sulphate supplement on wool and milk characteristics and lambs performance in naine ewes
تعداد 20 رأس میش نژاد نائینی 6+-24 ماهه، با میانگین وزن 2/3-+40 کیلوگرم، همراه با 20 رأس بره های آنها در قالب طرح کاملا تصادفی اثر بتائین و مکمل سولفات بر خصوصیات شیر و پشم و عملکرد بره ها بررسی شد. میش ها بطور تصادفی در چهار تیمار قرار گرفتند. تیمارها عبارت بودند از: 1-گروه شاهد 2-بتائین (05/0 درصد ماده خشک) 3-سولفات (24/0 سولفور درصد ماده خشک 4-بتائین هرماه با سولفات. جیره غذائی طبق nrc با مح...
15 صفحه اولHelical CT angiography in evaluation of live kidney donors.
BACKGROUND Live kidney donor evaluation mandates anatomical and functional assessment of the donor kidney. Helical computed tomography (CT) with advanced 3-D techniques provides detailed description of the vascular, parenchymal, and collecting system. METHODS We compared the accuracy of helical CT angiography with intra-operative findings in the evaluation of 102 live kidney donors. RESULTS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1996
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003109523