TiO2 based surface acoustic wave gas sensor with modified electrode dimensions for enhanced H2 sensing application
The design and optimization of nanostructure-based surface acoustic wave (SAW) gas sensor is analyzed based on TiO2 sensing layer and modified electrode dimensions. The sensitivity of the gas sensor depends upon the type of sensing layer used and active surface area obtained by varying the aspect ratio. The performance of the sensor is observed from 0.1ppm to 100ppm concentration of ...
متن کاملOptimal Design of a Polyaniline-Coated Surface Acoustic Wave Based Humidity Sensor
This paper presents an optimal design for a new humidity sensor composed of a dual-resonator oscillator configuration with an operation frequency of 300 MHz, and a polyaniline (PANI) coating deposited along the resonation cavity of the sensing device. To improve the corrosion resistance of the sensor chip, Al/Au electrodes were used to form the SAW resonator. Prior to device fabrication, the co...
متن کاملLayered Surface Acoustic Wave Hydrogen Sensor Based on Polyethylaniline Nanofibers
Here we report on a layered Surface Acoustic Wave (SAW) gas sensor featuring polyethylaniline nanofibers as the active layer. A rapidly-mixed reaction was employed to synthesize polyethylaniline nanofibers. The product was deposited on a microfabricated ZnO/36° YX LiTaO3 SAW transducer. Scanning Electron Microscopy (SEM) and Ultraviolet-visible spectroscopy (UV-vis) were utilized to characteriz...
متن کاملPalladium nanoparticle-based surface acoustic wave hydrogen sensor.
Palladium (Pd) nanoparticles (5-20 nm) are used as the sensing layer on surface acoustic wave (SAW) devices for detecting H2. The interaction with hydrogen modifies the conductivity of the Pd nanoparticle film, producing measurable changes in acoustic wave propagation, which allows for the detection of this explosive gas. The nanoparticle-based SAW sensor responds rapidly and reversibly at room...
متن کاملA surface acoustic wave ICP sensor with good temperature stability.
BACKGROUND Intracranial pressure (ICP) monitoring is very important for assessing and monitoring hydrocephalus, head trauma and hypertension patients, which could lead to elevated ICP or even devastating neurological damage. The mortality rate due to these diseases could be reduced through ICP monitoring, because precautions can be taken against the brain damage. OBJECTIVE This paper presents...