Temperature rise and DC current capability tests of star-point reactor used in HVDC transmission

نویسندگان

چکیده

Star-point reactors are grounding devices installed in HVDC stations between the converter transformer secondary side and AC of arms to provide a reference ground. Such used as high-impedance on power transformers, providing high impedance path for fundamental harmonic (i.e. 50 or 60 Hz) low DC current, eliminating current flowing through windings. Temperature rise capability tests 420 kV star-point reactor presented this paper. The purpose temperature test is verify that temperatures can damage insulation will not be reached with specified service conditions. was carried out according requirements IEC 61869-3 standard client’s request which included simultaneous application fundamental, 3rd voltage excitation. inclusion excitation an amplitude up 15% simulates distortion may appear system at location installation. Prior test, performed. goal determine value saturation point reached. injected while applied. Two different cases considered regarding voltage: superimposed third harmonic. Test circuit proposed suitable generation complex voltages composed amplitudes applied also during it applicable testing HV equipment rated kV.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the role of russia in transmission of energy from central asia and caucuses to european union

پس ازفروپاشی شوروی،رشد منابع نفت و گاز، آسیای میانه و قفقاز را در یک بازی ژئوپلتیکی انرژی قرار داده است. با در نظر گرفتن این منابع هیدروکربنی، این منطقه به یک میدانجنگ و رقابت تجاری برای بازی های ژئوپلتیکی قدرت های بزرگ جهانی تبدیل شده است. روسیه منطقه را به عنوان حیات خلوت خود تلقی نموده و علاقمند به حفظ حضورش می باشد تا همانند گذشته گاز طبیعی را به وسیله خط لوله مرکزی دریافت و به عنوان یک واس...

15 صفحه اول

A New Topology of Bidirectional Buck-Boost dc/dc Converter with Capability of Soft Switching and input Current Ripple Cancellation

In this paper, a new bidirectional buck-boost dc-dc converter with capability of soft switching and zero input current ripple is proposed. The coupled inductor is used in the proposed converter to eliminate the input current ripple. In the proposed converter, zero voltage switching (ZVS) and zero current switching (ZCS) can be obtained for the main and auxiliary switches, respectively. In addit...

متن کامل

A Review on Protection Techniques used in HVDC Transmission Line

This paper highlights on the techniques used in the HVDC transmission line protection for the faults occurring at various locations. The different techniques deployed for HVDC protection includes Distance Protection technique, Discrete Fourier Transform technique, Artificial Neural Network technique, Fuzzy logic technique, Wavelet Transform technique, Natural Frequency technique, Independent co...

متن کامل

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energija

سال: 2022

ISSN: ['0354-8651', '2812-7528']

DOI: https://doi.org/10.37798/201867281