Test-retest reproducibility of a rapid method to measure brain oxygen metabolism

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Test-retest reproducibility of a rapid method to measure brain oxygen metabolism.

Cerebral metabolic rate of oxygen (CMRO(2)) is an important index of tissue viability and brain function, but this parameter cannot yet be measured routinely on clinical scanners. Recently, a noninvasive technique was proposed which estimates global CMRO(2) by concomitantly measuring oxygen-extraction-fraction using T(2)-relaxation-under-spin-tagging MRI and pulse oximetry, and cerebral-blood-f...

متن کامل

Test-retest reproducibility of [11C]-l-deprenyl-D2 binding to MAO-B in the human brain

BACKGROUND [11C]-L-deprenyl-D2 is a positron emission tomography (PET) radioligand for measurement of the monoamine oxidase B (MAO-B) activity in vivo brain. The estimation of the test-retest reproducibility is important for accurate interpretation of PET studies. RESULTS We performed two [11C]-L-deprenyl-D2 scans for six healthy subjects and evaluated the test-retest variability of this radi...

متن کامل

Test-retest reliability and reproducibility of short-echo-time spectroscopic imaging of human brain at 3T.

A 1H magnetic resonance spectroscopic imaging study at 3T and short echo time was conducted to evaluate both the reproducibility, as measured by the interscan coefficient of variation (CV), and test-retest reliability, as measured by the intraclass correlation coefficient (ICC), of measurements of glutamate (Glu), combined glutamate and glutamine (Glx), myo-inositol (mI), N-acetylaspartate, cre...

متن کامل

Test-retest reproducibility of 50 kHz linear-electrical impedance myography.

OBJECTIVE Electrical impedance myography (EIM) is a method for evaluating muscle in which high-frequency, low-intensity alternating current is applied to a body region and the resulting surface voltage pattern over a muscle of interest is measured. In this study, the reproducibility for the simplest of these techniques, 50 kHz linear-EIM, was assessed for three muscles. METHODS Fifty kilohert...

متن کامل

Reproducibility (test-retest) of vestibular evoked myogenic potential.

INTRODUCTION There is still no consensus in the literature as to the best acoustic stimulus for capturing vestibular evoked myogenic potential (VEMP). Low-frequency tone bursts are generally more effective than high-frequency, but recent studies still use clicks. Reproducibility is an important analytical parameter to observe the reliability of responses. OBJECTIVE To determine the reproducib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2012

ISSN: 0740-3194

DOI: 10.1002/mrm.24295