Testing a novel isokinetic dynamometer constructed using a 1080 Quantum
نویسندگان
چکیده
منابع مشابه
Eccentric and concentric isokinetic knee flexion and extension: a reliability study using the Cybex 6000 dynamometer.
OBJECTIVE To determine the reliability of the Cybex 6000 isokinetic dynamometer in measuring the knee muscle performance concentrically and eccentrically. METHODS 18 male and 12 female subjects with no previous knee injuries, who had not previously undergone any isokinetic testing, were studied. The flexor and extensor muscles groups of both knees were tested at 60 degrees s-1 and 120 degrees...
متن کاملVariability and reliability of the pendulum test for spasticity using a Cybex II isokinetic dynamometer.
I undertook this study to determine the test-retest variability and reliability of the pendulum test for muscle spasticity performed with the Cybex II isokinetic dynamometer. Thirty patients, with intracranial lesions and hemiplegia of 15 days' to 3 years' duration, were tested four times, consecutively. With the patients lying supine, the angle of flexion, at which the knee first reversed dire...
متن کاملA Novel Design of a Multi-layer 2:4 Decoder using Quantum- Dot Cellular Automata
The quantum-dot cellular automata (QCA) is considered as an alternative tocomplementary metal oxide semiconductor (CMOS) technology based on physicalphenomena like Coulomb interaction to overcome the physical limitations of thistechnology. The decoder is one of the important components in digital circuits, whichcan be used in more comprehensive circuits such as full adde...
متن کاملUnderstanding the effect of speed of exertion on isokinetic strength using a multiaxial dynamometer.
In this study a multiaxial isokinetic dynamometer was used to measure strength during various upper-body isokinetic exertions. Ten male participants performed 7 different upper-body isokinetic exertions. In addition, to evaluate the effect of speed on strength, each participant performed sitting pull exertions at the speed of 0.026, 0.130, and 0.260 m/s. Average isokinetic strength increased fr...
متن کاملValidity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength
PURPOSE To determine whether the handheld dynamometer (HHD) is an appropriate tool to assess and quantify peak hip extension strength in prone standing position by (1) evaluating the concurrent validity of the HHD versus an isokinetic dynamometer (IKD), (2) establishing the minimal detectable change (MDC), and (3) determining the validity of single-trial versus multi-trial measures. METHOD A ...