Testing LaMgAl11O19 crystal for x-ray spectroscopy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Al0.2Ga0.8As X-ray photodiodes for X-ray spectroscopy

Three custom-made Al0.2Ga0.8As p-i-n mesa X-ray photodiodes (200 μm diameter, 3 μm i layer) were electrically characterised and investigated for their response to illumination with soft X-rays from an Fe radioisotope X-ray source (Mn Kα = 5.9 keV; Mn Kβ = 6.49 keV). The AlGaAs photodiodes were shown to be suitable for photon counting X-ray spectroscopy at room temperature. When coupled to a cus...

متن کامل

X-ray Absorption Spectroscopy

X-ray absorptioń spectroscopy, today widely used as a tool for structural investigations, is described. Theoretically it is shown that above an absorption edge the absorption coefficient is well approximated by a sum of terms, each one describing a particular path followed by the photoelectron outgoing from the atom. Such geometrical feature allows to use X-ray absorption spectroscopy for struc...

متن کامل

X-ray Absorption Spectroscopy

1.59.1 PHYSICS OF X-RAY ABSORPTION 1 1.59.1.1 X-ray Absorption Edges 2 1.59.1.2 X-ray Fluorescence 3 1.59.1.3 Measurement of X-ray Absorption Spectra 3 1.59.2 EXTENDED X-RAY ABSORPTION FINE STRUCTURE 6 1.59.2.1 Theoretical Description of EXAFS Spectra 6 1.59.2.1.1 Single scattering 6 1.59.2.1.2 Multiple scattering 8 1.59.2.1.3 Other corrections to the EXAFS equation 9 1.59.2.2 Programs for Calc...

متن کامل

X-Ray Spectroscopy of Gamma-Ray Bursts

Observational evidence of iron absorption and emission lines in X-ray spectra of Gamma-Ray Bursts is quite compelling. I will briefly review the results, summarize different models and describe the connection with massive progenitors in star-forming regions implied by these results. This link is also supported by measurements of the X-ray absorbing gas in several GRB’s, with column density cons...

متن کامل

X-ray Absorption Spectroscopy Using X–ray Fluorescence Spectrometer

Strong characteristic Kα X-ray lines are accompanied by weak lines due to the radiative Auger effect (RAE) [1, 2]. The characteristic Kα fluorescent X-rays (K-L2,3 lines) are emitted by the 2p→1s electric dipole transition after one of the 1s electron photoionization, Though the probability is less than 0.01, one of the 2p electrons is excited into an unoccupied discrete or continuum level simu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2004

ISSN: 0034-6748,1089-7623

DOI: 10.1063/1.1785269