The CDF intermediate silicon layers detector
نویسندگان
چکیده
منابع مشابه
The intermediate silicon layers detector at CDFII: Design and progress
The Intermediate Silicon Layers Detector is presently being built as part of the CDF upgrades to prepare for the next Tevatron data taking run, scheduled to start in the year 2000. The ISL will be located in the radial region between the Silicon Vertex Detector and the Central Outer Tracker. It will add tracking in the forward region and signi cantly improve tracking in the central region. Toge...
متن کاملCDF TRACKING DOC PUBLIC August Proposal for Intermediate Silicon Layers in CDF
The CDF SVXII silicon detector will provide coverage to j j In the region j j the combination of the SVXII detector and the Central Open Cell Tracker COT will yield precise D tracking with high e ciency and purity For j j it may be possible to perform D tracking with SVXII alone but in the absence of larger radius hit information the impact parameter resolution for such tracks will be too poor ...
متن کاملSVX’, the new CDF silicon vertex detector
The Collider Detector at Fermilab (CDF) radiation hardened silicon vertex detector (SVX’) is described. The new detector has several improvements over its predecessor such as better signal to noise and higher efficiency. It is expected to have a radiation tolerance in excess of 1 Mrad. It has been taking data for several months and some preliminary results are shown.
متن کاملProgress in the construction of the CDF silicon vertex detector
The mechanical design and construction progress of the CDF silicon vertex detector is described. Results on the location accuracy of the silicon strip detectors are presented and indicate an initial placement uncertainty of less than 10 Wm. The water and gas cooling system, which is constructed of low mass materials and is used to remove heat from the readout electronics, is briefly described ....
متن کاملThe CDF Run IIb silicon detector: Design, preproduction, and performance
A new silicon microstrip detector was designed by the CDF collaboration for the proposed high-luminosity operation of the Tevatron pp̄ collider (Run IIb). The detector is radiation-tolerant and will still be functional after exposure to particle fluences of 10 1-MeV equivalent neutrons=cm and radiation doses of 20MRad. The detector will maintain or exceed the performance of the current CDF silic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Physics B - Proceedings Supplements
سال: 1999
ISSN: 0920-5632
DOI: 10.1016/s0920-5632(99)00562-9