The CDF MiniPlug calorimeters

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The CDF MiniPlug Calorimeters at the Tevatron

The CDF diffractive physics program relies on two MiniPlug (MP) calorimeters, which can detect both charged and neutral particles, to measure the event energy flow in the very forward rapidity region on opposite sides of the interaction point. The performance of a MP prototype is published in [1], while the final detector assembly and the results from a cosmic ray test are reported in [2].

متن کامل

The timing system for the CDF electromagnetic calorimeters

We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high-energy photons to verify that the photon is in time with the event collision, to reject cosmic-ray and beam-halo backgrounds, and to allow direct searches for new, heavy, long-lived ...

متن کامل

Ii Design Concept and Geant Simulation

Two MiniPlug calorimeters, designed to measure the energy and lateral position of particles in the (forward) pseudorapidity region of 3.6 < |η| < 5.2 of the CDF detector, have been recently installed as part of the Run II CDF upgrade at the Tevatron p̄p collider. They consist of lead/liquid scintillator read out by wavelength shifting fibers arranged in a pixel-type towerless geometry suitable f...

متن کامل

s . in s - de t ] 1 9 D ec 2 00 5 The Timing System for the CDF Electromagnetic Calorimeters

We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify that the photon is in time with the event collision, to reject cosmic ray and beam halo backgrounds, and to allow direct searches for new heavy long-lived pa...

متن کامل

The RHIC Zero Degree Calorimeters

High Energy collisions of nuclei usually lead to the emission of evaporation neutrons from both “beam” and “target” nuclei. At the RHIC heavy ion collider with 100GeV/u beam energy, evaporation neutrons diverge by less than 2 milliradians from the beam axis. Neutral beam fragments can be detected downstream of RHIC ion collisions (and a large aperture Accelerator dipole magnet) if θ ≤ 4 mr but ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 2003

ISSN: 0168-9002

DOI: 10.1016/s0168-9002(02)01764-3