The coated cathode conductive layer chamber
نویسندگان
چکیده
منابع مشابه
Tests of Cathode Strip Chamber Prototypes
We report on the results of testing two six-layer 0:6 0:6 m cathode strip chamber (CSC) prototypes in a muon beam at CERN. The prototypes were designed to simulate sections of the end-cap muon system of the Compact Muon Solenoid (CMS) detector which will be installed at the Large Hadron Collider (LHC). We measured the spatial and time resolutions of each chamber for different gains, different o...
متن کاملA novel fluffy conductive polypyrrole nano-layer coated PLLA fibrous scaffold for nerve tissue engineering.
In this study, a novel three-dimensional fluffy PPy conductive fibrous scaffold (3D-cFSs) was fabricated by electrospinning technique combined with situ surface polymerization. Chemical compositions, morphology were characterized by fourier transform infrared (FTIR) and scanning electron microscopy (SEM). The results showed that the average diameter of PPy coated PLLA fibers in the 3D-cFSs was ...
متن کاملStudy of the T0 Cathode Strip Chamber Prototype at FNAL
A two-layer Cathode Strip Chamber prototype for the CMS Endcap Muon System has been constructed and tested at FNAL. The results of chamber characteristic measurements with cosmic rays are presented in this paper.
متن کاملThe Cathode Strip Chamber Data Acquisition System for CMS
The Cathode Strip Chamber (CSC) [1] Data Acquisition (DAQ) system for the CMS [2] experiment at the LHC [3] will be described. The CSC system is large, consisting of 218K cathode channels and 183K anode channels. This leads to a substantial data rate of ~1.5GByte/s at LHC design luminosity (10cms) and the CMS first level trigger (L1A) rate of 100KHz. The DAQ system consists of three parts. The ...
متن کاملDormant Cathode Plasma Properties and Erosion Analysis in a Multiple-Cathode, High-Power, Rectangular Discharge Chamber
A high-power, rectangular discharge chamber is being investigated by the University of Michigan for operation with multiple discharge cathode assemblies (DCAs). The multiple cathode approach attempts to increase thruster lifetime by operating three DCAs sequentially, possibly providing a threefold increase in discharge life. Previous multiplecathode electric propulsion devices, such as the SPT-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1991
ISSN: 0168-9002
DOI: 10.1016/0168-9002(91)91000-l