The effects of distal interlocking screws on torsional stability in three-part intertrochanteric hip fractures
نویسندگان
چکیده
منابع مشابه
The effects of distal interlocking screws on torsional stability in three-part intertrochanteric hip fractures
OBJECTIVE Many surgeons currently use long cephomedullary nails for the treatment of intertrochanteric fractures. The optimal indications for deploying distal interlocks are still debatable. This study examined the torsional biomechanical properties of 3-part intertrochanteric femur fractures in a cadaveric bone model using two different distal fixation strategies, an unlocked long cephalomedul...
متن کاملIntramedullary Nails Result in More Reoperations Than Sliding Hip Screws in Two-part Intertrochanteric Fractures
BACKGROUND Sliding hip screws (SHSs) and intramedullary (IM) nails are well-documented implants for simple two-part intertrochanteric fractures; however, there is no consensus regarding which type of implant is better. QUESTIONS/PURPOSES We asked whether patients with simple two-part intertrochanteric fractures treated with IM nailing had (1) a lower reoperation rate and (2) less pain and bet...
متن کاملthe effects of changing roughness on the flow structure in the bends
flow in natural river bends is a complex and turbulent phenomenon which affects the scour and sedimentations and causes an irregular bed topography on the bed. for the reason, the flow hydralics and the parameters which affect the flow to be studied and understand. in this study the effect of bed and wall roughness using the software fluent discussed in a sharp 90-degree flume bend with 40.3cm ...
Complications of cement-augmented dynamic hip screws in unstable type intertrochanteric fractures--a case series study.
BACKGROUND Polymethylmethacrylate (PMMA) cement-augmented dynamic hip screws (DHS) have been used as a solution in unstable intertrochanteric fractures (ITF). Our aim was to investigate the complications in PMMA cement-augmented DHS. METHODS All patients who had received DHS plate osteosynthesis with or without PMMA cement augmentation from August 2005 to July 2009 in one medical center were ...
متن کاملUnreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third tibial fractures.
PURPOSE To assess the outcome of unreamed intramedullary nailing through the lateralised entry point using oblique proximal and biplanar distal interlocking screws. METHODS 15 men and 3 women aged 25 to 58 (mean, 37) years underwent unreamed intramedullary nailing with oblique proximal and biplanar distal interlocking screws for proximal third metaphyseal tibial fractures. The entry point was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: SpringerPlus
سال: 2015
ISSN: 2193-1801
DOI: 10.1186/s40064-015-1196-z