The Electrolytic Separation Factor of Tritium
نویسندگان
چکیده
منابع مشابه
factor influencing the adoption of internet banking
دوره مشترک کارشناسی ارشد بازاریابی و تجارت الکترونیک دانشگاه تربیت مدرس_ دانشگاه تکنولوژی lule? چکیده پایان نامه عوامل موثر بر پذیرش اینترنت بانک توسط مشتریان پیشرفت فناوری اطلاعات و ارتباطات و به طور خاص رشد اینترنت جهت تراکنش های معاملات بازرگانی، تاثیر بسیار عمیقی در صنعت بانکداری داشته است.این در حالی ست که نفوذ بانکداری اینترنتی در کشورهای در حال توسعه بسیار کندتر از نفوذ آن ...
15 صفحه اولUncertainty of the tritium dose conversion factor.
Environmental releases of tritium oxide at a number of Department of Energy nuclear weapons facilities contribute to a significant portion of environmental dose. Several conversion factors are utilized in the estimation of human impact from these releases, e.g., dispersion coefficients, consumption rates, uptake factors, transport factors, dose conversion factors, and risk coefficients. A proba...
متن کاملStudy of Concentration of Helium and Tritium in Electrolytic Cells with Excess Heat Generation
Concentrations of helium and tritium in gas and liquid phases in calorimetric cells with excess heat generations were measured. Values of factor F (nuclear ash) defined as ratio of amount of heat released by particular nuclear reactions to the excess heat, were calculated to be F(He in gas phase)≈ (4±16)×10 and F(T in liquid phase)≈ (8±6)×10, and upper limit of F(T in gas phase)≤ 1×10. These ex...
متن کاملSeparation of Hydrogen Isotopes ELECTROLYTIC MIGRATION THROUGH A PALLADIUM MEMBRANE
With the increasing importance of “ heavy water” as a moderator in nuclear reactors there arises a pressing need for a more efficient method of separating hydrogen isotopes. In a report by 0. N. Salmon to the U.S. Atomic Energy Commission (AEC Research and Development Report KAPL 1272) a process is described which aims to improve the method of separation by the electrolysis of water. This proce...
متن کاملMeasurement of extremely (2) H-enriched water samples by laser spectrometry: application to batch electrolytic concentration of environmental tritium samples.
RATIONALE Natural water samples artificially or experimentally enriched in deuterium ((2) H) at concentrations up to 10,000 ppm are required for various medical, environmental and hydrological tracer applications, but are difficult to measure using conventional stable isotope ratio mass spectrometry. METHODS Here we demonstrate that off-axis integrated cavity output (OA-ICOS) laser spectromet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Chemical Physics
سال: 1950
ISSN: 0021-9606,1089-7690
DOI: 10.1063/1.1747645