The Fermi level as an energy reference in liquid jet X-ray photoelectron spectroscopy studies of aqueous solutions

نویسندگان

چکیده

Adding a known redox couple to an aqueous solution gives liquid-jet XPS natural energy reference, the Fermi level.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of X-ray spot size on liquid jet photoelectron spectroscopy

A 30 µm pinhole is introduced in the intermediate focus of the SIM beamline at the Swiss Light Source to improve the spot size at the second downstream focus, which is used here for liquid jet X-ray photoelectron spectroscopy experiments. The 30 µm pinhole reduces the beam dimensions from 250 (v) × 100 (h) µm to 75 × 45 µm for a vertical exit slit of 100 µm. The smaller X-ray spot results in a ...

متن کامل

High-resolution soft X-ray photoelectron spectroscopy of liquid water.

High-resolution soft X-ray photoelectron spectra of liquid water (H(2)O and D(2)O) were measured using a liquid beam photoelectron spectrometer. The 1a(1) (O1s) band and the lowest valence 1b(1) band had single peaks, which is not consistent with the split 1b(1)→ 1a(1) of the X-ray emission band of liquid water if the splitting is assumed to originate from level shifts in two different hydrogen...

متن کامل

X-Ray Photoelectron Spectroscopic Studies of Dolomite Surfaces Exposed to Undersaturated and Supersaturated Aqueous Solutions

Cleaved surfaces of dolomite were studied using ex-situ X-ray photoelectron spectroscopy (XPS) following exposure of the surfaces to various experimental conditions. Dolomite samples exposed to air, to a highly undersaturated solution (0.1 M NaCl, pH = 9), and to solution with a supersaturation ( Dl/kT) of 5.5 (pH = 9) were investigated with semiquantitative methods of analysis to ascertain the...

متن کامل

Using “Tender” X-ray Ambient Pressure X-Ray Photoelectron Spectroscopy as A Direct Probe of Solid-Liquid Interface

We report a new method to probe the solid-liquid interface through the use of a thin liquid layer on a solid surface. An ambient pressure XPS (AP-XPS) endstation that is capable of detecting high kinetic energy photoelectrons (7 keV) at a pressure up to 110 Torr has been constructed and commissioned. Additionally, we have deployed a "dip &pull" method to create a stable nanometers-thick aqueous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Chemistry Chemical Physics

سال: 2021

ISSN: ['1463-9076', '1463-9084']

DOI: https://doi.org/10.1039/d1cp01511g