The forced oscillation technique in clinical practice: methodology, recommendations and future developments
نویسندگان
چکیده
منابع مشابه
ERS TASK FORCE The forced oscillation technique in clinical practice: methodology, recommendations and future developments
The forced oscillation technique in clinical practice: methodology, recommendations and future developments. E. Oostveen, D. MacLeod, H. Lorino, R. Farré, Z. Hantos, K. Desager, F. Marchal, on behalf of the ERS Task Force on Respiratory Impedance Measurements. #ERS Journals Ltd 2003. ABSTRACT: The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mecha...
متن کاملThe forced oscillation technique in clinical practice: methodology, recommendations and future developments.
The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report ...
متن کاملForced oscillation technique: from theory to clinical applications.
The forced oscillation technique (FOT) allows the noninvasive assessment of the mechanical properties of the respiratory system. Given that the technique does not require patient cooperation, it is suitable for the routine evaluation of respiratory function in a variety of clinical applications. In this paper, the rationale and the most conventional equipment and data processing of the techniqu...
متن کاملThe forced oscillation technique in intubated, mechanically-ventilated patients.
In a recent discussion concerning the use of the forced oscillation technique (FOT), PRIDE [ 1] stated that, although anaesthesia and intensive care are among the obvious areas of application of the method, there is very little information on these applications. The paper by PEsuN et al. [2] in the present issue of the Journal describes one of the first attempts to apply the FOT to mechanically...
متن کاملForced oscillation technique and spirometry in cold air provocation tests.
BACKGROUND Impedance measurements by the forced pseudo random noise oscillation technique can be used to study the mechanical characteristics of the respiratory system. The objective of this study was to analyse the changes in impedance to a cold air provocation test in patients with asthma, and to correlate these changes with those in the forced expiratory volume in one second (FEV1). METHOD...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Respiratory Journal
سال: 2003
ISSN: 0903-1936,1399-3003
DOI: 10.1183/09031936.03.00089403