The Level-1 Tile-Muon Trigger in the Tile Calorimeter upgrade program
نویسندگان
چکیده
منابع مشابه
The ATLAS Tile Calorimeter Test Beam Monitoring Program
During 2003 test beam session for ATLAS Tile Calorimeter a monitoring program has been developed to ease the setup of correct running condition and the assessment of data quality. The program has been built using the Online Software services provided by the ATLAS Online Software group. The first part of this note contains a brief overview of these services followed by the full description of Ti...
متن کاملThe PHENIX Muon Trigger Upgrade
The PHENIX muon trigger upgrade adds Level-1 trigger detectors to existing forward muon spectrometers and will enhance the ability of the experiment to pursue a rich program of spin physics in polarized proton collisions at √ s = 500 GeV . The additional muon trigger detectors and Level-1 trigger electronics will allow the experiment to select high momentum muons from the decay of W -bosons and...
متن کاملDesign of a 22 Scintillating Tile Package for the Sdc Barrel Electromagnetic Tile/fiber Calorimeter
We describe R&D results on optical properties of a scintillating tile//ber system for the SDC barrel electromagnetic calorimeter. The tile//ber system uses a wavelength shifting ber to readout the signal of a scintillating plate (tile) and a clear ber to transmit the signal to a phototube. In the SDC calorimeter design, four of tile//ber systems are grouped as a 22 tile package so that the gap ...
متن کاملEvent filter monitoring with the ATLAS tile calorimeter
The ATLAS Tile Calorimeter detector is presently involved in an intense phase of subsystems integration and commissioning with muons of cosmic origin. Various monitoring programs have been developed at different levels of the data flow to tune the set-up of the detector running conditions and to provide a fast and reliable assessment of the data quality already during data taking. This paper fo...
متن کاملNoise Characterization of the ATLAS Tile Calorimeter Readout System
It is shown that the addition of a low pass RC filter to the current ATLAS Tile Calorimeter 3-in-1 card decreases the high frequency noise. A peak in the output voltage is found for 29 Mhz input noise but is filtered out by the same low pass filter.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2016
ISSN: 1748-0221
DOI: 10.1088/1748-0221/11/12/c12049