The Liquid Argon Purity Demonstrator
نویسندگان
چکیده
منابع مشابه
Purity Monitor Studies in Medium Liquid Argon TPC
This paper is an attempt to describe some of the results that had been found through a journey of study in the field of particle physics. This study consists of two parts, one about the measurement of the cross section of the decay of the Z particle in two electrons, and the other deals with the measurement of the cross section of the multi-photon absorption process using a beam of Laser in the...
متن کاملIonization of liquid argon by a particles
From an analysis of electron pulses in liquid argon produced by a particles the average energy required to form an ion pair is evaluated, assurmng JaEk’s theory of columnar recombination is valid. The mean value of 26.0 ev found in this way agrees well with the corresponding value of 26.4 ev for a particles m argon gas. Application of Jaffk’s theory to the liquid state is discussed, and from th...
متن کاملElectron scattering and transport in liquid argon.
The transport of excess electrons in liquid argon driven out of equilibrium by an applied electric field is revisited using a multi-term solution of Boltzmann's equation together with ab initio liquid phase cross-sections calculated using the Dirac-Fock scattering equations. The calculation of liquid phase cross-sections extends previous treatments to consider multipole polarisabilities and a n...
متن کاملSupernova Relic Neutrinos in Liquid Argon detectors
We study the possibility of detecting the background of Supernova Relic Neutrinos (SRN) with liquid Argon Time Projection Chamber (TPC) detectors. As far as this study is concerned, these experimental devices are mainly sensitive to electron neutrino signals, and could provide further information on both Supernova explosion mechanism and star formation rate at redshifts z ≤ 1. We study in detai...
متن کاملA Regenerable Filter for Liquid Argon Purification
A filter system for removing electronegative impurities from liquid argon is described. The active components of the filter are adsorbing molecular sieve and activated-copper-coated alumina granules. The system is capable of purifying liquid argon to an oxygen-equivalent impurity concentration of better than 30 parts per trillion, corresponding to an electron drift lifetime of at least 10 ms. R...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2014
ISSN: 1748-0221
DOI: 10.1088/1748-0221/9/07/p07005