The mechanisms for detecting compressively sampled gratings
نویسندگان
چکیده
منابع مشابه
The mechanisms for detecting compressively sampled gratings
Contrast thresholds for sine-wave gratings are raised when the gratings are compressively sampled into a set of narrow bright bars on a dark background, even though this method of sampling preserves the mean luminance and contrast of the grating. Burr et al. [(1985). Vision Research, 25, 717-727] suggested threshold elevation was due to localized luminance adaptation to the sample bars, whose a...
متن کاملNon-Negative Matrix Factorisation of Compressively Sampled Non-Negative Signals
The new emerging theory of Compressive Sampling has demonstrated that by exploiting the structure of a signal, it is possible to sample a signal below the Nyquist rate and achieve perfect reconstruction. In this short note, we employ Non-negative Matrix Factorisation in the context of Compressive Sampling and propose two NMF algorithms for signal recovery—one of which utilises Iteratively Rewei...
متن کاملRespiratory Motion Correction for Compressively Sampled Free Breathing Cardiac MRI Using Smooth l1-Norm Approximation
Transformed domain sparsity of Magnetic Resonance Imaging (MRI) has recently been used to reduce the acquisition time in conjunction with compressed sensing (CS) theory. Respiratory motion during MR scan results in strong blurring and ghosting artifacts in recovered MR images. To improve the quality of the recovered images, motion needs to be estimated and corrected. In this article, a two-step...
متن کاملRecovery of Non-Negative Signals from Compressively Sampled Observations Via Non-Negative Quadratic Programming
The new emerging theory of Compressive Sampling has demonstrated that by exploiting the structure of a signal, it is possible to sample a signal below the Nyquist rate and achieve perfect reconstruction. In this paper, we consider a special case of Compressive Sampling where the uncompressed signal is non-negative, and propose an extension of Non-negative Quadratic Programming—which utilises It...
متن کاملApparent contrast of spatially and temporally sampled gratings.
We have measured the apparent contrast of spatially and temporally sampled gratings having the spatial frequency of 2, 4 and 8 c/deg. A contrast matching task was used in two different sampling conditions which allowed us to stimulate selectively the sustained and transient mechanisms in spatial and temporal vision. The results demonstrate the visual interpolation characteristics in the two dom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Vision Research
سال: 1997
ISSN: 0042-6989
DOI: 10.1016/s0042-6989(97)00070-9