The microstrip gas chamber
نویسندگان
چکیده
منابع مشابه
The gas proportional scintillation counter / microstrip gas chamber hybrid detector
The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedba...
متن کاملThe feasibility of using microstrip gas detector as radon detector for earthquake prediction
In the last decade, several studies have concluded that elevated concentrations of radon gas in soil or groundwater could be the sign of an imminent earthquake. It is believed that in case of sudden movement of rocks before earthquake, radon is released from the depth of ground and reached the surface. In this way, by measuring Radon concentration change, earthquake prediction is possible. In t...
متن کاملAn Analysis of Gas Flow in the BaBar Drift Chamber
An analysis based on the Green’s function for the diffusion equation indicates that the BaBar drift chamber could be purged of air down to 1 ppm in 8 hours with a purge gas velocity in the chamber of 0.043 cm/s, corresponding to one volume change every 2 hours. Anecdotal evidence from CLEO and ALEPH supports this claim. • It is proposed that the gas be fed into the chamber through 64 holes of 1...
متن کاملContouring of Gas-dynamic Contour of the Chamber
Fuel after inflaming burns at high (till 15-20 МПа and more) pressure, thus is formed gaseous combustion products with temperature 3000-4500 K, which effuse to the ambient space through the nozzle. On length of the nozzle the temperature and pressure of them decrease, and the velocity increases, passing through a sound velocity in minimum (critical) cross-section of the nozzle and reaching 2700...
متن کاملEffect of gas composition on CMS Cathode Strip Chamber performance
Cathode strip chambers (CSCs) are multiwire proportional counters that will be used as muon detectors in the Compact Muon Solenoid (CMS) experiment at the European Center for Nuclear Research (CERN). The composition of the gas inside the chamber influences important chamber parameters, such as gas gain and operational voltage range. Differences in these parameters were examined under variations...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Physics B - Proceedings Supplements
سال: 1991
ISSN: 0920-5632
DOI: 10.1016/0920-5632(91)90056-k