The modified balloon crush technique
نویسندگان
چکیده
منابع مشابه
Massive hemoptysis successfully treated by modified bronchoscopic balloon tamponade technique.
A 60-year-old man with massive hemoptysis was treated successfully by modified bronchoscopic balloon tamponade technique. Compared with previously reported techniques, the modified technique requires no special catheter, no complicated maneuver, and is able to be applied to more massive bleeding.
متن کاملBifurcation coronary lesions and the "crush" technique.
aggregometry (LTA) is the most widely reported ex vivo technique to assess aspirin effect in platelets (1–3). With respect to our study potentially underestimating aspirin resistance in patients with unstable coronary syndromes, it should be noted that 23% (n 47) of our percutaneous coronary intervention (PCI) patients were in that category. All of these patients were sensitive to aspirin (4). ...
متن کاملBifurcation Coronary Lesions Treated With the “Crush” Technique
icardo A. Costa, MD,* Gary S. Mintz, MD, FACC,* Stephane G. Carlier, MD, PHD,* lexandra J. Lansky, MD, FACC,* Issam Moussa, MD, FACC,* Kenichi Fujii, MD,* ideo Takebayashi, MD,* Takenori Yasuda, MD,* Jose R. Costa, JR, MD,* Yoshihiro Tsuchiya, MD,* isette O. Jensen, MD, PHD,† Ecaterina Cristea, MD,* Roxana Mehran, MD, FACC,* eorge D. Dangas, MD, PHD, FACC,* Sriram Iyer, MD, FACC,‡ Michael Colli...
متن کاملModified technique of realtime ultrasound guided percutaneous balloon dilatational tracheostomy through laryngeal mask airway insertion
Background The technique of bedside percutaneous tracheostomy (BPT) has become a routine procedure in the ICU. As a common standard, a bronchoscope is used during the BPT in order to assess the upper airway anatomy and to assist guiding the needle while penetrating the tracheal inter-ring space into the correct central positioning. However, using the bronchoscope during the puncture of the trac...
متن کاملBalloon-assisted enteroscopy using a single-balloon technique.
teroscopy system (Olympus Medical Systems Europa GmbH, Hamburg, Ger− many; l" Fig. 1) consists of a high−resolu− tion endoscope (XSIF−Q160Y) with a working length of 200 cm, and an outer diameter of 9.2 mm, and a flexible over− tube (XST−BY3A; l" Fig. 2) with a working length of 132 cm and an outer diameter of 13.2 mm. A latex−free balloon is only attached at the tip of the single−use sili− con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medicine
سال: 2018
ISSN: 0025-7974,1536-5964
DOI: 10.1097/md.0000000000012808