THE NATIONAL SYNCHROTRON LIGHT SOURCE
نویسندگان
چکیده
منابع مشابه
Biomolecular solution X-ray scattering at the National Synchrotron Light Source
In recent years there has been a growing interest in the application of X-ray scattering techniques to biomolecules in solution. At NSLS, a new undulator-based beamline, X9, has been constructed to address the oversubscribed user demand for X-ray scattering. Beamline X9 has the capability to perform small/wide-angle X-ray scattering (SAXS/WAXS) all in one single instrument. This is accomplished...
متن کاملPerformance of new infrared beamline U12IR at the National Synchrotron Light Source
The instrumentation and performance of the new infrared beamline U12IR at the National Synchrotron Light Source of Brookhaven National Laboratory is described. This beamline utilizes infrared synchrotron radiation from a bending magnet. A combination of beamline design features and spectroscopic instrumentation allows the facility to reach the extremely low frequency limit of ;2 cm ~i.e., 60 GH...
متن کاملX27A—A new hard X-ray micro-spectroscopy facility at the National Synchrotron Light Source
A new hard X-ray micro-spectroscopy beamline has recently been installed at bending-magnet beamline X27A at the National Synchrotron Light Source, where the focus of research is primarily directed towards the environmental, geological and materials science communities. This instrument delivers moderate, 10 mm spatial resolution using achromatic dynamically bent Kirkpatrick–Baez mirrors, in addi...
متن کاملMirror-based X-ray Fluorescence Microprobes at the Advanced Photon Source and the National Synchrotron Light Source
High-energy synchrotrons are valuable sources of highly collimated, intense X-ray radiation for use in X-ray microprobe analysis including trace element quantification (X-ray fluorescence), chemical speciation determinations (X-ray absorption fine structure spectroscopy) and phase identification (X-ray diffraction). Kirkpatrick-Baez mirrors are being increasingly utilized for production of X-ra...
متن کاملLayout of the Absorbers for the Synchrotron Light Source Anka
The 2.5 GeV Synchrotron Light Source ANKA is now under construction at the Research Center in Karlsruhe. For a designed current of 400 mA, a power of 250 kW is radiated by the circulating e-beam in the 16 dipole magnets. 90% of the synchrotron radiation (SR) is absorbed by the 32 crotch absorbers in the dipole and the adjacent ante chamber, the remaining 10 % by distributed absorbers in the str...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of the New York Academy of Sciences
سال: 1980
ISSN: 0077-8923,1749-6632
DOI: 10.1111/j.1749-6632.1980.tb47206.x